Bonilla Asalde, César AntonioCallata Cisneros, Veronica EstherPeralta Ccuno, Maribel Eulalia2019-02-012019-02-012018-11-25https://hdl.handle.net/20.500.13053/2511Objective: To analyze the evidence on the effectiveness of adequate humidity in incubators to prevent heat loss in the premature newborn. Material and methods: Of the articles reviewed, 10% (N= 1/10) his design is systematic reviews, 20% (N= 2/10) are meta-analysis, 30% (N= 3/10) are descriptive, 10% (N= 1/10) is transversal analytical, 10% (N=1/10) is controlled and randomized clinical trials, 10% (N=1/10) is cases and controls and 10% (N=1/10) is prospective. According to the strength of recommendation strong 30%, weak 40% and very weak 30%, according to the country where the investigations were carried out, there were found: France 40%, Brazil 20%, USA 30% and Argentina 10% respectively. Results: According to the review, it is evident that 100% of the articles (N = 10/10) point out the effectiveness of adequate humidity in incubators to prevent excessive heat loss in the premature newborn. Conclusion: It is concluded that the systematic review of the 10 scientific articles points out the effectiveness of adequate humidity in incubators to prevent heat loss in the premature newborn, because it manages to maintain a balance between the partial vapor pressure of the water close to the skin and the surrounding air, thus avoiding high insensible losses due to evaporation and therefore preventing heat loss.OBJETIVO: ANALIZAR LAS EVIDENCIAS SOBRE LA EFECTIVIDAD DE LA HUMEDAD ADECUADA EN INCUBADORAS PARA PREVENIR LA PÉRDIDA DE CALOR EN EL RECIÉN NACIDO PREMATURO. MATERIAL Y MÉTODOS: DE LOS ARTÍCULOS REVISADOS EL 10% (N= 1/10) SU DISEÑO ES REVISIONES SISTEMÁTICAS, EL 20% (N= 2/10) SON META-ANÁLISIS, 30%(N= 3/10) SON DESCRIPTIVOS, EL 10% (N= 1/10) ES TRANSVERSAL ANALÍTICO, 10% (N=1/10) ES ENSAYOS CLÍNICOS CONTROLADOS Y ALEATORIZADOS, 10% (N=1/10) ES CASOS Y CONTROLES Y 10% (N=1/10) ES PROSPECTIVO. DE ACUERDO A LA FUERZA DE RECOMENDACIÓN FUERTE 30%, DÉBIL 40% Y MUY DÉBIL 30%, SEGÚN EL PAÍS DONDE SE REALIZARON LAS INVESTIGACIONES SE ENCONTRARON: FRANCIA 40%, BRASIL 20%, EEUU 30% Y ARGENTINA 10% RESPECTIVAMENTE. RESULTADOS: SEGÚN LA REVISIÓN SE EVIDENCIA QUE LOS ARTÍCULOS EL 100% (N = 10/10) SEÑALAN LA EFECTIVIDAD DE LA HUMEDAD ADECUADA EN INCUBADORAS PARA PREVENIR LA PÉRDIDA EXCESIVA DE CALOR EN EL RECIÉN NACIDO PREMATURO. CONCLUSIÓN: SE CONCLUYE QUE LA REVISIÓN SISTEMÁTICA DE LOS 10 ARTÍCULOS CIENTÍFICAS SEÑALA LA EFECTIVIDAD DE LA HUMEDAD ADECUADA EN INCUBADORAS PARA PREVENIR LA PÉRDIDA DE CALOR EN EL RECIÉN NACIDO PREMATURO, PORQUE LOGRA MANTENER UN EQUILIBRIO ENTRE LA PRESIÓN PARCIAL DE VAPOR DE LAS AGUA PRÓXIMOS A LA PIEL Y EL AIRE CIRCUNDANTE, EVITANDO ASÍ LAS ALTAS PERDIDAS INSENSIBLES POR EVAPORACIÓN Y POR LO TANTO PREVINIENDO LA PÉRDIDA DE CALOR.application/pdfspahttp://purl.org/coar/access_right/c_14cbhttps://creativecommons.org/licenses/by-nc-sa/4.0/Incubadoras para LactantesHumedadRecién nacido prematuroIncubators, InfantHumidityInfant, PrematureEffectiveness of adequate humidity in incubators to prevent heat loss in premature newbornsEfectividad de la humedad adecuada en incubadoras para prevenir la pérdida de calor en el recién nacido prematuroEFFECTIVENESS OF ADEQUATE HUMIDITY IN INCUBATORS TO PREVENT HEAT LOSS IN THE PREMATURE NEWBORNhttp://purl.org/coar/resource_type/c_7a1fhttp://purl.org/pe-repo/ocde/ford#3.03.03ODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades