Effectiveness of the Sterrad hydrogen peroxide plasma method for optimizing sterilization of temperature-sensitive medical devices
| dc.contributor.advisor | Matta Solis, Hernán Hugo | |
| dc.contributor.author | Muñoz Mendoza, Margot Alejandrina | |
| dc.contributor.author | Zegarra López, Mariela Roxana | |
| dc.date.accessioned | 2019-02-19T16:16:50Z | |
| dc.date.available | 2019-02-19T16:16:50Z | |
| dc.date.issued | 2018-08-25 | |
| dc.description.abstract | The objective is to systematically analyze the evidence on the effectiveness of the sterrad hydrogen peroxide plasma method to optimize the sterilization of thermosensitive medical devices. Material and Methods: The Systematic Review is an Observational and Retrospective Research Design, Subjected to Critical Selection Using the Grade Evaluation System for the Identification of the Degree of Evidence in the Following Databases: Pudmed, Redalyc, Cochrane, Sciencederect, Researchgte, Bvs And Lylacs. Of the 5 Articles Reviewed, 60% were Randomized Clinical Trials and 40% were Quantitative Studies of Process Costs. 60% of the studies were carried out in the US, 20% in Italy and 20% in Austria. Results of the evidence found, 100% of the studies conclude that the sterrad hydrogen peroxide plasma method is effective in optimizing the sterilization of thermosensitive medical instruments and is directly related to the decontamination method previously used. In the Cost Evaluation (40%) it is obtained that despite the high cost of the sterrad system, in the long term it shows economic effectiveness in technology. Conclusion: The Sterrad Hydrogen Peroxide Plasma Method is Effective in Optimizing the Sterilization of Thermosensitive Medical Devices. | en_US |
| dc.description.abstract | El Objetivo Es Analizar Sistemáticamente Las Evidencias Sobre La Eficacia Del Método Plasma De Peróxido De Hidrogeno sterrad Para Optimizar La Esterilización De Dispositivos Médicos Termosensibles. Material Y Métodos: La Revisión Sistemática Es Un Diseño De Investigación Observacional Y Retrospectiva, Sometido A Selección Critica Utilizando El Sistema De Evaluación Grade Para La Identificación Del Grado De Evidencia En La Siguiente Bases De Datos: Pudmed, Redalyc, Cochrane, Sciencederect, Researchgte, Bvs Y Lylacs. De Los 5 Artículos Revisados, El 60% En Ensayos Clínicos Aleatorios Y El 40% Estudios Cuantitativos De Costos Por Proceso. El 60% De Los Estudios Se Realizaron En EEUU, El 20% En Italia Y El 20 % Austria. Resultados De Las Evidencias Encontradas, 100% De Los Estudios Concluyen Que El Método Plasma De Peróxido De Hidrogeno sterrad Es Efectivo Para Optimizar La Esterilización Del Instrumental Médico Termosensible Y Esta Directamente Relacionado Con El Método De Descontaminación Usado Previamente. En La Evaluación De Costos (40%) Se Obtiene Que A pesar Del Costo Elevado Del Sistema sterrad, A Largo Plazo Muestra Eficacia Económica En Tecnología. Conclusión: El Método Plasma De Peróxido De Hidrogeno Sterrad Es Eficaz Para Optimizar La Esterilización De Dispositivos Médicos Termosensibles. | es_ES |
| dc.description.researcharea | Salud, enfermedad y ambiente | |
| dc.format | application/pdf | |
| dc.identifier.uri | https://hdl.handle.net/20.500.13053/2604 | |
| dc.language.iso | spa | es_ES |
| dc.language.iso | spa | |
| dc.publisher | Universidad Privada Norbert Wiener | es_ES |
| dc.publisher.country | PE | es_ES |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.source | Repositorio Institucional de la Universidad Privada Norbert Wiener | es_ES |
| dc.subject | Esterilización | es_ES |
| dc.subject | Equipos y Suministros | es_ES |
| dc.subject | Peróxido de Hidrógeno | es_ES |
| dc.subject | Sterilization | es_ES |
| dc.subject | Equipment and Supplies | es_ES |
| dc.subject | Hydrogen Peroxide | es_ES |
| dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#3.03.03 | |
| dc.subject.ods | ODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades | |
| dc.title | Effectiveness of the Sterrad hydrogen peroxide plasma method for optimizing sterilization of temperature-sensitive medical devices | en_US |
| dc.title | Eficacia del método plasma de peróxido de hidrógeno Sterrad, para optimizar la esterilización en dispositivos médicos termosensibles | es_ES |
| dc.title.alternative | Efficiency of the Sterrad Hydrogen Peroxide plasma method, to optimize Sterilization in thermosensitive medical devices | es_ES |
| dc.type | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| renati.advisor.dni | 10689893 | |
| renati.advisor.orcid | https://orcid.org/0000-0001-7403-6717 | |
| renati.author.dni | 01334446 | |
| renati.author.dni | 29591274 | |
| renati.discipline | 021209 | |
| renati.juror | Calsin Pacompea, Wilmer | |
| renati.juror | Pérez Siguas, Rosa Eva | |
| renati.juror | Remuzgo Artezano, Anika | |
| renati.level | https://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad | |
| renati.type | https://purl.org/pe-repo/renati/type#trabajoAcademico | |
| thesis.degree.discipline | Segunda Especialidad de Gestión en Central de Esterilización | es_ES |
| thesis.degree.grantor | Universidad Privada Norbert Wiener. Facultad de Ciencias de la Salud | es_ES |
| thesis.degree.level | Título de Segunda Especialidad | es_ES |
| thesis.degree.name | Especialista de Gestión en Central de Esterilización | es_ES |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- TRABAJO ACADÉMICO Muñoz Margot - Zegarra Mariela.pdf
- Tamaño:
- 531.6 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Bloque de licencias
1 - 1 de 1
Cargando...

- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: