Examinando por Materia "Óxido de Etileno"
Mostrando 1 - 5 de 5
- Resultados por página
- Opciones de ordenación
Ítem Acceso abierto Effectiveness of ethylene oxide in the sterilization process of polymer materials(Universidad Privada Norbert Wiener, 2018-08-04) Fuentes Vasquez, Irma de Guadalupe; Tejerina Vegazo, Dany Marcell; Gamarra Bustillos, CarlosThe data search examined the effectiveness of ethylene oxide in polymeric materials. According to the results obtained from the systematic review, they show that, of the total of 10 articles reviewed, 30% (3) of these correspond to the United States, 30% (3) correspond to Brazil, 10% (1) correspond to Cuba , 10% (1) corresponds to Guatemala, 10% (1) to Venezuela and 10% (1) to Argentina. Conclusions: The systematic review of the 10 scientific articles on the effectiveness of ethylene oxide in polymer material, all of them correspond to the type and design of experimental studies - clinical trial. It was evident in the research reviewed that there is greater effectiveness of ethylene oxide in polymer material due to its great effectiveness; perfect for thermosensitive materials since sterilization is done at low temperature, which guarantees non-deformation and non-destruction of the elements; excellent diffusion coefficient in packaging, in places of difficult accessibility and penetration into folds; and the process does not alter the physical qualities of the sterilized product.Ítem Acceso abierto Effectiveness of Ethylene Oxide Sterilization in Narrow Lumen Thermosensitive Medical Devices(Universidad Privada Norbert Wiener, 2021-09-05) Huamán Allca, Sofía Felipa; Román Obregón, Carmen Rosa; Mori Castro, Jaime AlbertoObjective: To systematize evidence on the effectiveness of ethylene oxide sterilization processes for medical devices with narrow lumens. Material and method: This research has a quantitative approach, and the design is a systematic review. A total of 10 scientific articles were reviewed, which were subjected to critical reading and analyzed using the Grade system to identify the level of quality of the evidence. Results: Of the 10 articles analyzed, 100% (n=10/10) indicate that the ethylene oxide sterilization method for thermosensitive medical devices with lumens or hollow structures is effective due to its strong bactericidal, viricidal, and fungicidal properties, and above all, its high penetrating power and compatibility with all materials. Conclusions: The scientific evidence allows us to conclude that ethylene oxide as a sterilizing agent is effective for devices with narrow lumens due to its high penetrability, and it does not damage or deform the material being sterilized.Ítem Acceso abierto Effectiveness of reprocessed medical devices sterilized with low-temperature hydrogen peroxide plasma or ethylene oxide gas(Universidad Privada Norbert Wiener, 2018-12-04) Dávila Esteban, Gladys Cecilia; Reyes Muñoz de Antonio, Gladys; Calsin Pacompia, WilmerSystematize evidence on the effectiveness of reprocessed medical devices in low-temperature sterilization with hydrogen peroxide plasma or ethylene oxide gas. Materials and methods: The academic work responds to the quantitative approach and systematic review design with a population of 15 articles and 10 were taken as a sample. The instrument used was the search in databases such as Cochrane, Lilacs, Pubmed, Medline, Epistemonikos , Intramed and Scielo, the ten studies found according to the type of research, 10% (1/10) belong to a systematic review, 80% (8/10) are applied experimental and the 10% (1/10) transversal; 60% of the studies are from Brazil and 10% from Spain, Colombia, Peru and Taiwan respectively. To evaluate the articles, the GRADE Method was used, which measures the quality of evidence and the strength of recommendation. Results: Of the 10 articles reviewed, 70% (n=07/10) show that low temperature reprocessing with hydrogen peroxide plasma or ethylene oxide gas affects the operation of medical devices and has a direct positive correlation with the increase in the number of reprocessing.Publicación Acceso abierto EFICACIA DEL ÓXIDO DE ETILENO EN EL PROCESO DE ESTERILIZACIÓN EN MATERIAL DE POLÍMEROS(Universidad Privada Norbert Wiener, 2018-08-04) Tejerina Vegazo, Dany Marcell; Gamarra Bustillos, CarlosEn la búsqueda de datos se examinó la eficacia del óxido de etileno en material polímeros. Según los resultados obtenidos de la revisión sistemática, muestran que, del total de 10 artículos revisados, que el 30% (3) de estos corresponden a Estados Unidos, 30% (3) corresponden a Brasil, 10% (1) corresponde a Cuba, 10% (1) corresponde a Guatemala, 10% (1) de Venezuela y un 10% (1) a Argentina. Conclusiones: La revisión sistemática de los 10 artículos científicos sobre eficacia del óxido de etileno en material polímero, todos ellos corresponden al tipo y diseño de estudios experimentales- ensayo clínico. Se evidenció en las investigaciones revisadas que existe mayor eficacia del óxido de etileno en material de polímeros por su gran eficacia; perfecto para los materiales termosensibles ya que la esterilización se hace a baja temperatura, lo que garantiza la no deformación y la no destrucción de los elementos; excelente coeficiente de difusión en envoltorios, en lugares de difícil accesibilidad y penetración en los pliegues; y el proceso no altera a las calidades físicas del producto esterilizado.Publicación Acceso abierto Factores de riesgo por óxido de etileno y satisfacción laboral del personal de enfermería en central de esterilización de un hospital de Lima 2024(Universidad Privada Norbert Wiener, 2025-02-02) Beteta Jaime, Adriana Elizabeth; Benavides Silva de Sender, Erika María del CarmenEl uso del Óxido de Etileno en las Centrales de Esterilización, pueden ocasionar en el personal diversas alteraciones que perjudican a su salud, debido al componente químico altamente toxico inclusive pudiendo provocar el cáncer, considerándolo como una enfermedad ocupacional, por ello se planteó como objetivo general determinar la relación entre los factores de riesgo por óxido de etileno y satisfacción laboral del personal de enfermería en central de esterilización de un hospital de Lima 2024. El estudio es de tipo descriptivo porque va describir las características de ambas variables la independiente con la dependiente y correlacional para comprobar si ambas variables se correlacionen entre sí. Trabajaremos con una población y muestra de 80 profesionales de salud del Hospital Alberto Sabogal Sologuren, usando una muestra censal por criterio de la investigadora, ya que la población es pequeña o finita, por lo que no es necesario seleccionar una muestra, además se tiene acceso a todos los trabajadores que conforman la población. Se empleará los instrumentos tanto para la satisfacción laboral como el instrumento para los factores de riesgo por OE de Guardino, que fueron ya validados por juicios de expertos y aplicados en nuestro país. El Alpha de Cronbach para el primer y segundo instrumento es de 0.979 y 0.995 por lo que deducimos que las herramientas con la que trabajaremos son muy fiables. Por último, se procederá a construir una base de datos mediante el programa SPSS v.23 para realizar el análisis estadístico correspondiente y para establecer la relación que existe entre ambas variables, se emplearan pruebas estadísticas no paramétrica (correlación Rho de Spearman).
