    PublicaciónAcceso abierto
    Leadcare II Comparison with Graphite Furnace AtomicAbsorption Spectrophotometry for Blood Lead Measurementin Peruvian Highlands
    (Springer, 2022-05-30) Rosales-Rimache, Jaime; Chavez-Ruiz, Manuel; Inolopú-Cucche, Jorge; Rabanal-Sanchez, Jhonatan; Rueda-Torres, Lenin; Sanchez-Holguin, Gloria
    Peru is one of the countries with the highest leadcontamination in the world. Biological monitoring has lim-itations due to the shortage of laboratories with validatedmethodologies for the measurement of blood lead, and it isnecessary to use alternative methods for its measurement inhigh-altitude cities. We aimed to compare the blood leadlevels (BLL) measured by the LeadCare II (LC) method andGraphite Furnace Atomic Absorption Spectrometry (GF-AAS). We measured the BLL of 108 children from the city ofLa Oroya. The mean and median BLL for GF-AAS were10.77±4.18 and 10.44lg/dL, respectively; for the LCmethod, the mean was 11.71±4.28 and the median was11.60lg/dL. We found a positive linear correlation(Rho = 0.923) between both methods. Notwithstanding, theWilcoxon test suggests a significant difference between bothmethods (q= 0.000). In addition, the Bland–Altmananalysis indicates that there is a positive bias (0.94) in the LCmethod, and this method tends to overestimate the BLL.Likewise, we performed a generalized linear model toevaluate the influence of age and hemoglobin on BLL. Wefound that age and hemoglobin had a significant influence onBLL measured by the LC method. Finally, we used two non-parametric linear regression methods (Deming and Passing-Bablok regression) to compare the LC method with the GF-AAS. We found that these methods differ by at least a con-stant amount, and there would be a proportional differencebetween both. Although in general there is a positive linearcorrelation, the results of both methods differ significantly.Therefore, its use in cities located at high altitudes (higherthan 2440 m.a.s.l.) would not be recommended.
  • Cargando...
    Miniatura
    PublicaciónAcceso abierto
    Leadcare II Comparison with Graphite Furnace AtomicAbsorption Spectrophotometry for Blood Lead Measurementin Peruvian Highlands
    (Springer, 2022-05-22) Rosales-Rimach, Jaime; Chavez-Ruiz, Manuel; Inolopú-Cucche, Jorge; Rabanal-Sanchez, Jhonatan; Rueda-Torres, Lenin; Sanchez-Holguin, Gloria S
    Peru is one of the countries with the highest leadcontamination in the world. Biological monitoring has lim-itations due to the shortage of laboratories with validatedmethodologies for the measurement of blood lead, and it isnecessary to use alternative methods for its measurement inhigh-altitude cities. We aimed to compare the blood leadlevels (BLL) measured by the LeadCare II (LC) method andGraphite Furnace Atomic Absorption Spectrometry (GF-AAS). We measured the BLL of 108 children from the city ofLa Oroya. The mean and median BLL for GF-AAS were10.77±4.18 and 10.44lg/dL, respectively; for the LCmethod, the mean was 11.71±4.28 and the median was11.60lg/dL. We found a positive linear correlation(Rho = 0.923) between both methods. Notwithstanding, theWilcoxon test suggests a significant difference between bothmethods (q= 0.000). In addition, the Bland–Altmananalysis indicates that there is a positive bias (0.94) in the LCmethod, and this method tends to overestimate the BLL.Likewise, we performed a generalized linear model toevaluate the influence of age and hemoglobin on BLL. Wefound that age and hemoglobin had a significant influence onBLL measured by the LC method. Finally, we used two non-parametric linear regression methods (Deming and Passing-Bablok regression) to compare the LC method with the GF-AAS. We found that these methods differ by at least a con-stant amount, and there would be a proportional differencebetween both. Although in general there is a positive linearcorrelation, the results of both methods differ significantly.Therefore, its use in cities located at high altitudes (higherthan 2440 m.a.s.l.) would not be recommended.
Más sobre Wiener...
  • Admisión
  • Nosotros
  • Bolsa de trabajo
  • Posgrado
  • Portal para el estudiante
  • Contáctenos
  • Libro de Reclamaciones
  • Transparencia
  • Canal Ético
Carreras
  • Farmacia y Bioquímica
  • Tecnología Médica en Terapia Física y Rehabilitación
  • Tecnología Médica en Laboratorio Clínico y Anatomía Patológica
  • Psicología
  • Odontología
  • Obstetricia
  • Nutrición y Dietética
  • Medicina Humana
  • Enfermería
  • Arquitectura
  • Ingeniería Civil
  • Ingeniería de Sistemas e Informática
  • Ingeniería Industrial y de Gestión Empresarial
  • Derecho y Ciencia Política
  • Administración y Marketing
  • Contabilidad y Auditoría
  • Administración y Negocios Internacionales
  • Administración y Dirección de Empresas
  • Administración en Turismo y Hotelería
  • Comunicación en Medios Digitales
Centros Wiener
  • Centro de Análisis Clínicos
  • Centro Odontológico
  • Centro de Terapia Física y Rehabilitación
Servicios
  • Biblioteca
  • Responsabilidad Social
  • Registros Académicos
  • Secretaría General
  • Bienestar Estudiantil
  • Dirección de Empleabilidad y Alumni
  • Defensoría Universitaria
Novedades
  • Eventos
  • Noticias
  • Info Wiener
  • Boletín de Calidad
  • Wiener Guía del Estudiante Pregrado
  • Trabaja con Nosotros
Jr. Larraburre y Unanue 110 Lima
Av. Arequipa 440 Lima
Jr. Saco Oliveros 150 Lima
Av. Arenales 1555 Lince
Escríbenos:
administrador.repositorio@uwiener.edu.pe
Síguenos en:
Sistema DSPACE 7 - Metabiblioteca | logo