Publicación:
Eventos adversos a dispositivos médicos en el Hospital San Juan de Lurigancho, 2018 a 2022. Lima 2023

dc.contributor.advisorCaldas Herrera, Emma
dc.contributor.authorVasquez Díaz, Marisol Estefany
dc.contributor.authorBerrocal Ramos, Elba
dc.date.accessioned2024-05-17T16:38:28Z
dc.date.available2024-05-17T16:38:28Z
dc.date.issued2024-02-28
dc.description.abstractThis research was conducted at the San Juan de Lurigancho Hospital in Lima, with the general objective of identifying adverse events related to medical devices reported at the hospital. The study was descriptive in type, with a non-experimental, cross-sectional design, using a deductive method and a quantitative approach. The population and sample consisted of 124 reports of suspected adverse incidents related to medical devices between 2018 and 2022. The data collection technique was documentary analysis, using a data collection form specifically designed for this research. Results: No severe adverse events were reported; 96.8% of the adverse events notified were mild, and 0.8% were moderate. Furthermore, 90.3% of adverse events occurred during the use of the medical device, and in 44.4% of cases, the probable cause was poor device quality. The main consequence of adverse events was device loss, which occurred in 72.6% of cases. Conclusion: At the San Juan de Lurigancho Hospital, between 2018 and 2022, most adverse events related to medical devices occurred in patients during device use, had mild consequences, and were likely attributable to poor device quality.en_US
dc.description.abstractLa presente investigación se realizó en el Hospital San Juan de Lurigancho de la ciudad de Lima y tuvo como objetivo general identificar los eventos adversos a dispositivos médicos presentados en el Hospital San Juan de Lurigancho. Esta investigación es de tipo descriptiva y el diseño es de nivel descriptivo, no experimental, de corte transversal, con un método deductivo y enfoque cuantitativo. La población y la muestra estuvo constituida por 124 notificaciones de sospechas de incidentes adversos a dispositivos médicos entre los años 2018 al 2022. La técnica utilizada para la recopilación de datos es la del análisis documental utilizando una ficha de recopilación de datos diseñada para esta investigación. Los resultados arrojaron que no se presentaron eventos adversos graves, mientras que el 96,8% de los eventos adversos notificados fueron leves y el 0,8% moderados. Asimismo, se identificó que el 90,3% de los eventos adversos ocurrieron durante el uso del dispositivo médico y que la causa probable del 44.4% de los eventos adversos fue la mala calidad del dispositivo médico. Por otro lado, la principal consecuencia de los eventos adversos fue la pérdida del dispositivo médico ocurrido en 72,6% de los casos. De la investigación se concluye que en el Hospital San Juan de Lurigancho, durante los años 2018 y 2022, la mayor incidencia de eventos adversos a dispositivos médicos ocurrió en pacientes, durante el uso del dispositivo y tuvo consecuencias leves probablemente debido a la mala calidad del dispositivo médico.es_ES
dc.description.researchareaSalud y Bienestar
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/11137
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wiener
dc.publisher.countryPE
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wiener
dc.subjectEquipment and Suppliesen_US
dc.subjectEquipos y Suministroses_ES
dc.subjectHospitals, Publicen_US
dc.subjectHospitales Públicoses_ES
dc.subjectPatient Safetyen_US
dc.subjectSeguridad del Pacientees_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.01.05
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleEventos adversos a dispositivos médicos en el Hospital San Juan de Lurigancho, 2018 a 2022. Lima 2023es_ES
dc.title.alternativeAdverse events to medical devices, at the San Juan De Lurigancho Hospital, 2018 to 2022. Lima 2023en_US
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dspace.entity.typePublication
renati.advisor.dni08738787
renati.advisor.orcidhttps://orcid.org/0000-0003-1501-2090
renati.author.dni40601191
renati.author.dni70074670
renati.discipline917046
renati.jurorLlahuilla Quea, José Antonio
renati.jurorPinedo Panduro, Lauro Sócrates
renati.jurorRespicio López, Patricia Milagros
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineFarmacia y Bioquímica
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Farmacia y Bioquímica
thesis.degree.levelTítulo profesional
thesis.degree.nameQuímico Farmacéutico

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
T061_40601191_70074670_T.pdf
Tamaño:
1.47 MB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
FORM_40601191_70074670_T.pdf
Tamaño:
1.13 MB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
TURNITIN_40601191_70074670_T.pdf
Tamaño:
1.23 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: