Publicación:
Implementación del método de filtración por membrana empleando el sistema de filtración EZ-FIT™ en análisis microbiológico de agua purificada en laboratorio de caramelos farmacéuticos en el periodo de mayo–octubre del 2019

dc.contributor.advisorGuevara Vicaña, Rita Aurora
dc.contributor.authorMinaya Laureano, Maribel Florencia
dc.date.accessioned2021-02-09T23:53:41Z
dc.date.available2021-02-09T23:53:41Z
dc.date.issued2020-11-27
dc.description.abstractThe objective of this thesis was to compare the implementation of the membrane filtration method using the EZ-FITTM filtration system in a pharmaceutical candy laboratory for the analysis of purified water. The research design was observational, analytical, and descriptive. The study confirmed that the percentage of recovery for the inoculated microorganisms was greater than 70%. It was also evident that the data had a normal distribution, which allowed for the use of the Student's t-test to compare the results of both methods, with a 95% confidence level for the intervals of microbial counts. The comparison was made between the TSA agar medium method and the EZ-FITTM membrane filtration method. This work determined that the mean differences in CFU recovery for E. coli, P. aeruginosa, and S. aureus cultures were not statistically significant, meaning that either technique would provide satisfactory results. Ultimately, according to its established procedures, the laboratory decides which method to apply, prioritizing the benefits of its management.en_US
dc.description.abstractEl presente trabajo de tesis, tiene por objetivo: Comparar la implementación del método de filtración por membrana empleando el sistema de filtración EZ-FITTM en Laboratorio de caramelos farmacéuticos en el análisis de agua purificada para uso farmacéutico. El diseño de investigación es observacional, analítico y descriptivo y nos permitió comprobar que el porcentaje de recuperación del microorganismo inoculado fue mayor a 70%, así mismo se evidencio que los datos presentaron una distribución normal, lo cual nos permitiría emplear para comparar los resultados de ambos métodos la prueba estadística de t-student, con un nivel de confianza de 95 % para los intervalos de sus resultados en el recuento microbiano usando medio agar TSA y en el recuento microbiano usando el método de filtración por membrana empleando el sistema de filtración EZ-FITTM. Este trabajo determino que las diferencias de medias de recuperación de ufc de los cultivos de E. coli, P. aeruginosa y S. aureus no son estadísticamente significativas por lo que usar cualquiera de las dos técnicas mostraría resultados satisfactorios; no obstante, el laboratorio de acuerdo a sus procedimientos establecidos, es quien decide la aplicación de cualquiera de ellos, anteponiendo para ello los beneficios de la gestión.es_ES
dc.description.researchareaSalud, Enfermedad y Ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/4243
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wiener
dc.publisher.countryPE
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wiener
dc.subjectFiltrationen_US
dc.subjectWater Microbiologyen_US
dc.subjectFiltraciónes_ES
dc.subjectTechnology, Pharmaceuticalen_US
dc.subjectMicrobiología del Aguaes_ES
dc.subjectDrug Industryen_US
dc.subjectTecnología Farmacéuticaes_ES
dc.subjectIndustria Farmacéuticaes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.01.05
dc.subject.odsODS 9: Industria, innovación e infraestructura. Construir infraestructuras resilientes, promover la industrialización inclusiva y sostenible y fomentar la innovación
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleImplementación del método de filtración por membrana empleando el sistema de filtración EZ-FIT™ en análisis microbiológico de agua purificada en laboratorio de caramelos farmacéuticos en el periodo de mayo–octubre del 2019es_ES
dc.title.alternativeImplementation of the membrane filtration method using the Ez-FIT™ filtration system in microbiological analysis of purified water in the pharmaceutical candy laboratory in the period of May–October 2019en_US
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dspace.entity.typePublication
renati.advisor.dni10050333
renati.advisor.orcidhttps://orcid.org/0000-0002-8411-3410
renati.author.dni45948819
renati.discipline917046
renati.jurorBarteshagui Patiño, Mario Williams
renati.jurorCastillo Soto, Pedro
renati.jurorCiquero Cruzado, Mélida Merdeces
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineFarmacia y Bioquímica
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Farmacia y Bioquímica
thesis.degree.levelTítulo profesional
thesis.degree.nameQuímico Farmacéutico

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
T061_45948819_T.pdf
Tamaño:
7.06 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: