Publicación:
Determinación de la calidad de la materia prima celecoxib en seis lotes diferentes mediante los resultados de ensayos fisicoquímicos según USP 39, Lima 2016–2017

dc.contributor.advisorGuevara Ortega, Freddy Alberto
dc.contributor.authorFelipe Chávez, Ross Bereniz
dc.contributor.authorLázaro Cartolín, Johana Milagros
dc.date.accessioned2018-01-31T21:09:50Z
dc.date.available2018-01-31T21:09:50Z
dc.date.issued2017-11-25
dc.description.abstractThe present research work was conducted with the objective of determining the quality of celecoxib raw material in six different batches through the results of physicochemical tests according to USP 39. The study population consisted of six batches of raw material analyzed in the quality control area of a national pharmaceutical laboratory, during the period from May 2016 to February 2017. The research methodology was carried out in accordance with the specifications of the USP 39 technical standard. The results were: 100% compliant in description, 100% compliant in identification, 100% compliant in solubility, 100% compliant with less than 0.1% in water determination, 100% compliant with less than 0.2% in residue on ignition, 100% compliant with no more than 20 ppm of heavy metals, 100% compliant with no more than 0.5% in organic impurities, and 100% compliant in assay within a range of 98.0% – 102.0%. These results indicated that the celecoxib raw material from different batches, received by a national pharmaceutical laboratory during the period from May 2016 to February 2017, meets the quality standards established by USP 39, regardless of its place of origin.en_US
dc.description.abstractEl presente trabajo de investigación se desarrolló con el objetivo de determinar la calidad de la materia prima celecoxib en seis lotes diferentes mediante los resultados de ensayos fisicoquímicos según USP 39. La población fue seis lotes de materia prima analizadas en el área de control de calidad en un laboratorio farmacéutico nacional, durante el periodo comprendido entre mayo de 2016 hasta febrero de 2017. El método del trabajo de investigación se desarrolló según las especificaciones de la norma técnica USP 39.Los resultados fueron 100% conforme en descripción, 100% conforme en la Identificación, 100% conforme en la solubilidad, 100% conforme menor de 0,1 % en la determinación de agua, 100% conforme menor de 0,2 % en residuo de incineración, 100% conforme no más de 20 ppm en metales pesados, 100 % conforme no más de 0,5% en impurezas orgánicas y 100 % conforme en valoración con un rango de 98,0% - 102,0%. Estos resultados indicaron que la materia prima de celecoxib de diferentes lotes ingresada a un laboratorio farmacéutico nacional durante el periodo de mayo 2016 hasta febrero de 2017 es de calidad según las especificaciones de la USP 39, independientemente de su lugar de procedencia.es_ES
dc.description.researchareaSalud, Enfermedad y Ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/1003
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wiener
dc.publisher.countryPE
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wiener
dc.subjectControl de Calidades_ES
dc.subjectCelecoxibes_ES
dc.subjectQuality Controlen_US
dc.subjectQuímica Farmacéuticaes_ES
dc.subjectCelecoxiben_US
dc.subjectChemistry, Pharmaceuticalen_US
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.01.05
dc.subject.odsODS 9: Industria, innovación e infraestructura. Construir infraestructuras resilientes, promover la industrialización inclusiva y sostenible y fomentar la innovación
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleDeterminación de la calidad de la materia prima celecoxib en seis lotes diferentes mediante los resultados de ensayos fisicoquímicos según USP 39, Lima 2016–2017es_ES
dc.title.alternativeDetermination of the quality of the celecoxib raw material in six different lots using the results of physicochemical tests according to USP 39, Lima 2016–2017en_US
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
dspace.entity.typePublication
renati.advisor.dni09601903
renati.author.dni43803721
renati.author.dni46190163
renati.discipline917046
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineFarmacia y Bioquímica
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Farmacia y Bioquímica
thesis.degree.levelTítulo profesional
thesis.degree.nameQuímico Farmacéutico

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
TITULO - Lázaro Cartolín, Johana Milagros.pdf
Tamaño:
1.57 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: