Volumetric variation of two silicones by condensation SPEEDEX and ZETAPLUS when polymerizing over time

dc.contributor.advisorLlerena Meza De Pastor, Verónica
dc.contributor.authorDominguez Ruiz, Yamyr
dc.date.accessioned2022-05-02T16:51:54Z
dc.date.available2022-05-02T16:51:54Z
dc.date.issued2021-10-21
dc.description.abstractObjective: To compare in vitro the volumetric differences of two condensation silicones (Speedex and Zetaplus) at 5 and 30 minutes, 1, 24, and 48 hours. Materials and Methods: A total of 24 samples were obtained from two brands of heavy condensation silicones (Speedex and Zetaplus) in a 5cc³ matrix. The materials were activated and subsequently weighed on a sensitive digital scale at different times following activation. The volumes of the samples were calculated from the weights obtained and then compared. Results: Non-parametric Friedman's test and Student's t-test for independent groups were performed. The mean volumetric variation in the Zetaplus group was -0.00012 with a standard deviation of 0.00001, while the Speedex group showed a mean of -0.00009 with a standard deviation of 0.00002. Statistically significant differences were found between the two groups (p<0.05). At 30 minutes, volumetric variations were smaller but still significantly different between the silicones. Conclusions: Speedex heavy silicone exhibited significantly lower volumetric variation than Zetaplus silicone at 5 and 30 minutes, but not at later times. Both condensation silicones, Speedex and Zetaplus, showed significant volumetric variations at 5 and 30 minutes, 1 hour, 24 hours, and 48 hours.en_US
dc.description.abstractObjetivo: Comparar in vitro las diferencias volumétricas de dos siliconas de condensación (Speedex y Zetaplus), a los 5 y 30 minutos, 1, 24 y 48 horas Materiales y métodos: Se registraron 24 muestras entre dos marcas de siliconas pesadas de condensación (Speedex y Zetaplus) en una matriz de 5cc3, de los cuales fueron activadas y posteriormente pesadas en una balanza digital sensible en diferentes tiempos durante posterior a su activación. Con los pesos obtenidos se hallaron los volúmenes de las muestras las cuales fueron comparadas. Resultados: Para la investigación se realizó la prueba no paramétrica de Friedman y Prueba T de Student para comparar dos grupos independientes. Se observó que la media de las variaciones volumétricas en el grupo que utilizó Zeta Plus fue -0.00012 con una desviación estándar de 0.00001 y en el grupo de Speedex fue -0.00009 con una desviación estándar de 0.00002. Al comparar entre ambos grupos se encontró diferencias estadísticamente significativas (p<0.05). A los 30 minutos las variaciones volumétricas son menores, pero igualmente diferencias significativamente entre las dos siliconas. Conclusiones: La silicona pesada Speedex presentó, de manera significativa, menor variación volumétrica que la silicona Zetaplus a los 5 minutos y 30 minutos, mas no en los tiempos posteriores. La silicona por condensación Speedex y Zetaplus muestra variaciones al pasar los 5 y 30 minutos, 1 hora, 24 horas y 48 horas de manera significativa.es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/5933
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectSiliconas de condensaciónes_ES
dc.subjectVariación volumétricaes_ES
dc.subjectEstudio in vitroes_ES
dc.subjectCondensation siliconeses_ES
dc.subjectVolumetric variationes_ES
dc.subjectIn vitro studyes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleVolumetric variation of two silicones by condensation SPEEDEX and ZETAPLUS when polymerizing over timeen_US
dc.titleVariación volumétrica de dos siliconas por condensación SPEEDEX y ZETAPLUS al polimerizarse en el tiempoes_ES
dc.title.alternativeVolumetric variation of two silicones by condensation SPEEDEX and ZETAPLUS when polymerizing over timees_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni09920986
renati.advisor.orcidhttps://orcid.org/0000-0001-9146-0931
renati.author.dni46675015
renati.discipline911026
renati.jurorMeneses Gomez, Nadia Carolina
renati.jurorLuján Larreátegui, Haydeé Giovanna
renati.jurorRobles Montesinos, Ada Olinda
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineOdontologíaes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo Profesionales_ES
thesis.degree.nameCirujano Dentistaes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
T061_46675015_T.pdf
Tamaño:
3.28 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones