Interpretation of intrapartum electronic fetal monitoring and its relationship with the wellbeing of the newborn at Alberto Sabogal Sologuren Hospital, Callao - Lima 2020

dc.contributor.advisorAyala Peralta, Félix Dasio
dc.contributor.authorAsto Moreno, Haydee Zenaida
dc.date.accessioned2022-12-14T06:07:06Z
dc.date.available2022-12-14T06:07:06Z
dc.date.issued2021-09-03
dc.description.abstractDescriptive, correlational and retrospective study. The population: 300 pregnant women. Sample: 169 pregnant women. Dimensions: Normal pattern, suspicious pattern, pathological pattern, sociodemographic aspects of the mother, APGAR of the newborn and characteristics of the amniotic fluid. The age of the pregnant women ranged from 10 to 45 years. The findings of intrapartum fetal monitoring were presented in two groups, adolescents and adults, as follows: baseline fetal heart rate of 110-135 bpm: 47.93% and 30.18% respectively. Moderate variability 5-15 bpm: 43.20% and 22.49% respectively. The accelerations: 37.28% and 22.49% respectively. Tachycardia (160-170 bpm): 37.28% and 23.08% respectively; bradycardia (100-110 bpm): 21.30% and 17.75% respectively. Sinusoidal recording (3-4 cycles/min): 52.66% and 33.14% respectively. Likewise, intrapartum electronic fetal monitoring is significantly (p=0.000) related to sociodemographic aspects of the mother, the Apgar of the newborn and characteristics of the amniotic fluid.en_US
dc.description.abstractEstudio descriptivo, correlacional y retrospectivo. La población: 300 gestantes. Muestra: 169 gestantes. Dimensiones: Patrón normal, patrón sospechoso, patrón patológico, aspectos sociodemográficos de la madre, APGAR del recién nacido y características del líquido amniótico. La edad de las gestantes osciló entre los 10 a 45 años. Los hallazgos del monitoreo fetal intraparto fueron presentados en dos grupos, adolescentes y adultas como siguen: frecuencia cardiaca fetal basal de 110-135 lpm: 47.93% y 30.18% respectivamente. La variabilidad moderada 5-15 lpm: 43.20% y 22.49% respectivamente. Las aceleraciones: 37.28% y 22.49% respectivamente. Taquicardia (160-170 lpm): 37,28% y 23.08% respectivamente; bradicardia (100-110 lpm): 21.30% y 17.75% respectivamente. Registro sinusoidal (3-4 ciclos/min): 52.66% y 33.14% respectivamente. Asimismo, el monitoreo fetal electrónico intraparto está significativamente (p=0.000) relacionados con aspectos sociodemográficos de la madre, el Apgar del recién nacido y características del líquido amniótico.es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/7409
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectMonitoreo Fetales_ES
dc.subjectRecién Nacidoes_ES
dc.subjectHospitales Generaleses_ES
dc.subjectFetal Monitoringes_ES
dc.subjectInfant, Newbornes_ES
dc.subjectHospitals, Generales_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.03.03
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleInterpretation of intrapartum electronic fetal monitoring and its relationship with the wellbeing of the newborn at Alberto Sabogal Sologuren Hospital, Callao - Lima 2020en_US
dc.titleInterpretación del monitoreo fetal electrónico intraparto y su relación con el bienestar del recién nacido en el Hospital Alberto Sabogal Sologuren, Callao – Lima 2020es_ES
dc.title.alternativeInterpretation of intrapartum electronic fetal monitoring and its relationship with the well-being of the newborn at the Alberto Sabogal Sologuren hospital, Callao - Lima 2020.es_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni08476310
renati.advisor.orcidhttps://orcid.org/0000-0002-2830-3789
renati.author.dni17996208
renati.discipline915119
renati.jurorMorales Alvarado, Sabrina Ynés
renati.jurorSanz Ramírez, Ana María
renati.jurorAlfaro Fernández, Paul Rubén
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#trabajoAcademico
thesis.degree.disciplineSegunda Especialidad en Monitoreo Fetales_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista en Monitoreo Fetales_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
T061_17996208_S.pdf
Tamaño:
5.04 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones