Efficacy of the Harmonic Scalpel versus the Electronic Scalpel in patients undergoing surgery

dc.contributor.advisorCalsin Pacompia, Wilmer
dc.contributor.authorIbarra Santos, Natalie Edith
dc.contributor.authorRojas Julcarima, Gabriela Hanyely
dc.date.accessioned2022-12-13T05:10:24Z
dc.date.available2022-12-13T05:10:24Z
dc.date.issued2022-08-28
dc.description.abstractObjective: To analyze and systematize the evidence found on the effectiveness of the harmonic scalpel versus the electronic scalpel in patients undergoing surgery. Materials and Methods: The study was quantitative, and the study design was a systematic review. The instrument used was a database search: PubMed, Scielo, Epistemonikos, and EBSCO, with a population of 15 articles, and the sample consisted of 10 scientific articles published in scientific databases. The GRADE system was used to evaluate the selected articles. Results: Ten scientific articles on the effectiveness of the harmonic scalpel versus the electronic scalpel in patients undergoing surgery were reviewed. The systematic review of the articles, from a total of 100%, included 10% from Canada, 10% from Taiwan, 10% from Italy, 10% from China, 10% from Iraq, 10% from Spain, 10% from Brazil, 10% from Turkey, and 20% from India. Regarding the designs and studies, 10% were retrospective, 10% were randomized prospective trials, 10% were clinical trials, 30% were meta-analyses, and 40% were random cases. On the other hand, it was found that the use of the harmonic scalpel is more effective because it reduced the operative time, postoperative pain, intraoperative bleeding, and the patient's hospital stay. Conclusions: The use of the harmonic scalpel is 100% more effective than the electronic scalpel, but economically, there are limitations regarding the studies on the harmonic scalpel, which calls for the need for further studies.en_US
dc.description.abstractMateriales y Métodos: El tipo de estudio fue cuantitativo, el diseño del estudio fue revisión sistemática, el instrumento fue búsqueda de base de datos: PubMed, Scielo, Epistemonikos y EBSCO, con una población de 15 artículos y la muestra es de 10 artículos científicos publicados en las bases de datos científicos. Para la evaluación de los artículos seleccionados se utilizó el Sistema GRADE. Resultados: Se revisaron 10 artículos científicos sobre eficacia del bisturí armónico versus bisturí electrónico en pacientes sometidos a cirugía. La revisión sistemática de los artículos, del 100%; un 10% corresponden a Canadá, un 10% Taiwán, un 10% Italia, un 10% china, un 10% Irak, un 10% España, un 10% Brasil, un 10% Turquía y un 20% India. En relación de los diseños y estudios fueron un 10% retrospectivo, 10% Ensayo prospectivo aleatorizado, 10% Ensayo clínico, 30% meta-análisis, 40 % caso aleatorio. Por otro lado, se evidencia que el uso del bisturí armónico es más eficaz porque reduce el tiempo operatorio, el dolor post operatorio, reduce el sangrado intra operatorio y la estancia hospitalaria del paciente. Conclusiones: El uso del bisturí armónico es eficaz en 100% que el bisturí electrónico, pero en el ámbito económico hay limitaciones en cuanto los estudios del bisturí armónico encontrados, lo cual conlleva a la necesidad de analizar más estudios adicionales.es_ES
dc.description.researchareaSalud y Bienestar
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/7359
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectEficienciaes_ES
dc.subjectPacientes Internoses_ES
dc.subjectInstrumentos Quirúrgicoses_ES
dc.subjectEficienciaes_ES
dc.subjectInpatientses_ES
dc.subjectSurgical Instrumentses_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.03.03
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleEfficacy of the Harmonic Scalpel versus the Electronic Scalpel in patients undergoing surgeryen_US
dc.titleEficacia del Bisturí Armónico versus Bisturí Electrónico en pacientes sometidos a cirugíaes_ES
dc.title.alternativeEfficacy of the Harmonic Scalpel versus the Electronic Scalpel in patients undergoing surgeryes_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni41160310
renati.advisor.orcidhttps://orcid.org/0000-0002-8563-0057
renati.author.dni72529305
renati.author.dni47462842
renati.discipline913379
renati.jurorGonzales Saldaña, Susan Haydee
renati.jurorUturunco Vera, Milagros Lizbeth
renati.jurorCabrera Espezua, Jeannelly Paola
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#trabajoAcademico
thesis.degree.disciplineSegunda Especialidad en Enfermería en Centro Quirúrgicoes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista en Enfermería en Centro Quirúrgicoes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
T061_47462842_72529305_S.pdf
Tamaño:
262.15 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones