dc.description.abstractObjective: To establish safe disinfection processes in the sterilization center. Materials and Methods: Systematic reviews are an observational and retrospective study design that synthesizes the results of multiple primary studies. They are a core component of evidence-based nursing due to their rigorous methodology, identifying relevant studies to answer specific clinical practice questions. Results: In the final selection, 9 articles were chosen. We found that 55.5% (5) were from Brazil, 22.2% (2) were from Peru, and 11.1% (1) were from Colombia. A systematic review from Brazil constituted 11.1%. Cross-sectional studies were from Bogotá, Peru, and Brazil, while experimental studies came from Japan. Conclusions: The cleaning and disinfection process of endoscopes was not effective. The high-level disinfectant (2% glutaraldehyde) was ineffective after the tenth day of activation. High-level disinfection procedures were not optimally performed, with 6.7% of cultures showing positive results for various species of Pseudomonas. The luminometer is an instrument that allows the objective evaluation of quality control in disinfection processes in operating rooms.en_US
dc.description.abstractObjetivo: Establecer los procesos de desinfección seguros en la central de esterilización. Materiales y Métodos: Las Revisiones Sistemáticas son un diseño de investigación observacional y retrospectivo, que sintetiza los resultados de múltiples investigaciones primarias. Son parte esencial de la enfermería basada en la evidencia por su rigurosa metodología, identificando los estudios relevantes para responder preguntas específicas de la práctica clínica. Resultados: En la selección definitiva se eligieron 09 artículos, encontramos que el 55.5% (05) corresponden a Brasil, con un 22.2% (02) a Perú, mientras que con un 11.1% (01) corresponden a Colombia, respectivamente, una revisión sistemática correspondiente a Brasil, con un 11.1%. Tenemos estudios transversales correspondientes a Bogotá y Perú, Brasil, y además tenemos estudios experimentales correspondientes a Japón. Conclusiones: El proceso de limpieza y desinfección de los endoscopios no es efectivo. El desinfectante de alto nivel (glutaraldehído al 2%) no es efectivo después del décimo día de haber sido activado. Se determinó que los procedimientos de desinfección de alto nivel no se realizaron de manera óptima, hallando en un 6,7% cultivos positivos a pseudomonas de diferentes especies. El luminómetro es un instrumento que permite la evaluación objetiva del control de calidad en el proceso de desinfección en salas de cirugía.es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/453
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectDesinfecciónes_ES
dc.subjectDisinfectiones_ES
dc.subjectEsterilizaciónes_ES
dc.subjectSterilizationes_ES
dc.subjectMicrobiotaes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.03.03
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleSafe disinfection processes in the sterilization centeren_US
dc.titleProcesos de desinfección seguros en la central de esterilizaciónes_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni19836297
renati.advisor.orcidhttps://orcid.org/0000-0003-0706-7614
renati.author.dni27751206
renati.author.dni27743006
renati.discipline021209
renati.jurorMendigure Fernández, Julio
renati.jurorGómez Gonzales, Walter
renati.jurorCanales Rimachi, Reyda
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#trabajoAcademico
thesis.degree.disciplineSegunda Especialidad de Gestión en Central de Esterilizaciónes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista de Gestión en Central de Esterilizaciónes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
T061_27743006_S.pdf
Tamaño:
504.06 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones