Efficacy of the enzymatic detergent versus non-enzymatic detergent in the elimination of biofilm in cannulated instrumental

dc.contributor.advisorCalsin Pacompia, Wilmer
dc.contributor.authorHilario Povis, Rossana Inés
dc.contributor.authorOspino Dávila, Esther Carmen
dc.date.accessioned2019-01-21T15:09:00Z
dc.date.available2019-01-21T15:09:00Z
dc.date.issued2018-11-04
dc.description.abstractObjective: Systematize the evidence on the effectiveness of enzymatic detergent versus non-enzymatic detergent in biofilm removal from cannulated instruments. Materials and Methods: This study was quantitative, and the design was a systematic review, which is an observational and retrospective study that synthesizes the results of multiple primary studies. The population consisted of a total of 35 articles, and the sample included 08 articles. Data collection included full-text articles from the last ten years related to the issue, all of which were critically reviewed using the GRADE system to assign the quality of evidence and strength of recommendation. Results: The final selection consisted of 08 articles, of which (02) corresponded to China, (04) to Canada, (01) to Australia, and (01) to Switzerland, respectively. All are experimental studies. Conclusions: Out of the 08 reviewed articles, 75% (n=06/08) indicate that neither enzymatic detergent nor non-enzymatic detergent is effective in biofilm removal from cannulated instruments, compared to 25% (n=02/08) that show the effectiveness of non-enzymatic detergent in biofilm removal from cannulated instruments.en_US
dc.description.abstractObjetivo: Sistematizar las evidencias sobre la eficacia del detergente enzimático versus detergente no enzimático en la eliminación del biofilm en instrumental canulado. Materiales y Métodos: En este estudio, el tipo de investigación fue cuantitativo y el diseño fue una revisión sistemática, el cual es un estudio observacional y retrospectivo, que sintetiza los resultados de múltiples investigaciones primarias. La población fue un total de 35 artículos y la muestra de 08 artículos. En la recolección de datos se ha incluido a los artículos con texto completo, de los últimos diez años relacionados con el problema, todos se sometieron a una lectura crítica, utilizando el Sistema GRADE para asignar la calidad de evidencia y fuerza de recomendación. Resultados: En la selección definitiva se eligieron 08 artículos, encontramos (02) corresponden a China, (04) Canadá, (01) Australia y (01) suiza respectivamente. En su totalidad son estudios experimentales. Conclusiones: Del total de 08 artículos revisados que corresponden a la muestra, el 75 % (n=06/08) de estos evidencian que no es eficaz el detergente enzimático ni el detergente no enzimático en la eliminación del biofilm en instrumental canulado, en comparación de un 25 % (n=02/08) que evidencian la eficacia del detergente no enzimático en la eliminación del biofilm en instrumental canulado.es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/2429
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectEficienciaes_ES
dc.subjectEfficiencyes_ES
dc.subjectMateriales Biomédicos y Dentaleses_ES
dc.subjectBiomedical and Dental Materialses_ES
dc.subjectEquipo Dentales_ES
dc.subjectDental Equipmentes_ES
dc.subjectPlaca Dentales_ES
dc.subjectDental Plaquees_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.03.03
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleEfficacy of the enzymatic detergent versus non-enzymatic detergent in the elimination of biofilm in cannulated instrumentalen_US
dc.titleEficacia del detergente enzimático versus detergente no enzimático en la eliminación del biofilm en instrumental canuladoes_ES
dc.title.alternativeEFFICACY OF THE ENZYMATIC DETERGENT VERSUS NON-ENZYMATIC DETERGENT IN THE ELIMINATION OF BIOFILM IN CANULATED INSTRUMENTALes_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni41160310
renati.advisor.orcidhttps://orcid.org/0000-0002-8563-0057
renati.author.dni21262368
renati.author.dni20716997
renati.discipline021209
renati.jurorRivera Lozada De Bonilla, Oriana
renati.jurorCardenas de Fernández, Maria Hilda
renati.jurorÁvila Vargas-Machuca. Jeannette
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#trabajoAcademico
thesis.degree.disciplineSegunda Especialidad de Gestión en Central de Esterilizaciónes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista de Gestión en Central de Esterilizaciónes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
TESIS Hilario Rossana - Ospino Esther.pdf
Tamaño:
403.04 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones