Evaluation of the reproducibility of the position of the upper central incisor with and without the Andrews six-element orthodontists' head frontal plane indicator device.

dc.contributor.advisorNieto Perea, Patricia
dc.contributor.authorMachado Stevenson, Olga Beatriz
dc.date.accessioned2018-04-11T22:16:24Z
dc.date.available2018-04-11T22:16:24Z
dc.date.issued2018-02-05
dc.description.abstractThe present study evaluated the reproducibility of the upper central incisor (ICS) position, with and without the head's frontal plane indicator device, by orthodontists using the 6 elements of Andrews in 2016. The type and level of the research was prospective, longitudinal, and descriptive observational. The sample consisted of 29 orthodontists trained in the 6 elements philosophy, who took measurements at two times, with a 3-month interval between T1 and T2, with and without the frontal plane indicator device. At T1, using the device, a mean of -0.05mm (SD 2.69) was obtained, with statistically significant differences (p=0.04); and without the device, a mean of 2.62mm (SD 1.41) was found, with statistically significant differences (p=0.00). At T2, using the device, a mean of -1.55mm (SD 2.85) was obtained, with statistically significant differences (p=0.00); and without the device, a mean of 1.07mm (SD 1.65) was found, with no statistically significant differences (p=0.82). Both evaluated with a Gold Standard with a mean of 1mm (SD 1). The average over time with the device at T1 was statistically equal to the average at T2 (p=0.048). The study concluded that the greatest reproducibility is achieved using the Head's Frontal Plane Indicator Device.en_US
dc.description.abstractEl presente estudio evaluó la reproducibilidad de la posición del incisivo central superior (ICS), con y sin el dispositivo indicador del plano frontal de la cabeza, por ortodoncistas de los 6 elementos de Andrews en el año 2016. El tipo y nivel de la investigación fue prospectivo, longitudinal y descriptivo de observación. La muestra estuvo conformada por 29 ortodoncistas capacitados en la filosofía de los 6 elementos, los cuales realizaron las mediciones en dos tiempos, con un intervalo de 3 meses entre T1 y T2, con y sin el dispositivo indicador del plano frontal de la cabeza. En T1 empleando el dispositivo se obtuvo una media de -0.05mm (DS 2.69), existiendo diferencias estadísticamente significativas (p=0.04); y sin el dispositivo presentó una media de 2.62mm (DS de 1.41), existiendo diferencias estadísticamente significativas (p=0.00). En T2 utilizando el dispositivo se obtuvo una media de -1.55mm (DS 2.85), existiendo diferencias estadísticamente significativas (p=0.00); y sin dispositivo presento una media de 1.07mm (DS de 1.65), no existiendo diferencias estadísticamente significativas (p=0.82). Ambos evaluados con un Gold Standard con media de 1mm (DS 1). El promedio en el tiempo con dispositivo en T1 es estadísticamente igual al promedio de T2 (p=0.048). Concluyendo que la mayor reproducibilidad se da utilizando el dispositivo Indicador del Plano Frontal de la Cabeza.es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/1425
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectSalud Reproductivaes_ES
dc.subjectReproductive Healthes_ES
dc.subjectModulador del Elemento de Respuesta al AMP Cíclicoes_ES
dc.subjectModulador del Elemento de Respuesta al AMPces_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.03.23
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleEvaluation of the reproducibility of the position of the upper central incisor with and without the Andrews six-element orthodontists' head frontal plane indicator device.en_US
dc.titleEvaluación de la reproducibilidad de la posición del incisivo central superior con y sin el dispositivo indicador del plano frontal de la cabeza realizado por ortodoncistas de los seis elementos de Andrews.es_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni41356620
renati.advisor.orcidhttps://orcid.org/0000-0002-9354-2436
renati.discipline911269
renati.jurorLlanos Montalvo, Karina Beatriz
renati.jurorAlarcón Palacios, Omar Martin
renati.jurorPastor Arenas, Sandra Teresa
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#trabajoAcademico
thesis.degree.disciplineSegunda Especialidad en Ortodoncia y Ortopedia Maxilares_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista en Ortodoncia y Ortopedia Maxilares_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
TITULO - Machado Stevenson, Olga Beatriz.pdf
Tamaño:
1.07 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones