Relationship of pH and salival flow with the use of fixed orthodontic appliances in patients attended in the Dental Care Private Clinic - Lima, 2018
| dc.contributor.advisor | Garavito Chang, Enna Lucila | |
| dc.contributor.author | Pinedo Rufino, Yolita | |
| dc.date.accessioned | 2020-03-09T20:38:52Z | |
| dc.date.available | 2020-03-09T20:38:52Z | |
| dc.date.issued | 2019-12-11 | |
| dc.description.abstract | The purpose of this research was to determine the relationship between pH and salivary flow with the use of fixed orthodontic appliances in patients treated at the private clinic Dental Care, Lima 2018. The sample consisted of 50 participants aged 14 to 25 years, with 25 using orthodontic appliances and 25 not using appliances. An sterile container was provided to each patient to collect saliva accumulated over a five-minute period. A previously calibrated potentiometer was used to measure pH, and a graduated syringe was used to measure salivary flow. The bivariate analysis of pH and salivary flow with the study groups was conducted using chi-square and Mann-Whitney U tests, respectively. Prior to the test selection, data normality was verified using the Shapiro-Wilk test. A significance level of 5% was used. Results: Statistically significant differences were found, with a decrease in salivary pH and an increase in salivary flow in patients with orthodontic appliances compared to those without orthodontics. It is concluded that the use of orthodontic appliances alters the normal values of pH and salivary flow. | en_US |
| dc.description.abstract | El propósito del presente investigación fue determinar la relación del pH y flujo salival con el uso de aparatología ortodóntica fija en pacientes atendidos en la clínica privada dental Care- Lima 2018. La muestra estuvo constituida por 50 participantes entre 14 y 25 años, de los cuales el 25 con aparatología y 25 sin aparatología. Se proporcionó un frasco estéril a cada paciente para que la saliva acumulada fuese vaciada por un periodo de cinco minutos, para medir el pH se utilizó un potenciómetro previamente calibrado y la medición del flujo salival fue con una jeringa milimetrada. El análisis bivariado de las variables pH y flujo salival con los grupos de estudio se realizó mediante las pruebas chi cuadrado y U de Mann-Whitney, respectivamente. Previo a la elección de la prueba se verificó la normalidad de los datos por medio de la prueba de Shapiro-Wilk. Se trabajó con un nivel de significancia del 5%. Resultados: se obtuvo diferencias estadísticamente significativas apreciando una acidificación del pH salival y aumento de flujo salival con respecto a los pacientes sin ortodoncia. Se concluye que el uso de aparatología ortodóntica altera los valores normales del pH y flujo salival. | es_ES |
| dc.description.researcharea | Salud, enfermedad y ambiente | |
| dc.format | application/pdf | |
| dc.identifier.uri | https://hdl.handle.net/20.500.13053/3622 | |
| dc.language.iso | spa | es_ES |
| dc.language.iso | spa | |
| dc.publisher | Universidad Privada Norbert Wiener | es_ES |
| dc.publisher.country | PE | es_ES |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.source | Repositorio Institucional de la Universidad Privada Norbert Wiener | es_ES |
| dc.subject | Ortodoncia fija | es_ES |
| dc.subject | Flujo salival | es_ES |
| dc.subject | pH salival | es_ES |
| dc.subject | Aparatología ortodóntica | es_ES |
| dc.subject | Fixed orthodontics | es_ES |
| dc.subject | Salivary flow | es_ES |
| dc.subject | Salivary pH | es_ES |
| dc.subject | Orthodontic appliances | es_ES |
| dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.14 | |
| dc.subject.ods | ODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades | |
| dc.title | Relationship of pH and salival flow with the use of fixed orthodontic appliances in patients attended in the Dental Care Private Clinic - Lima, 2018 | en_US |
| dc.title | Relación entre el pH y flujo salival con el uso de aparatología ortodóntica fija en pacientes atendidos en la Clínica Privada Dental Care - Lima, 2018 | es_ES |
| dc.title.alternative | “Relationship of pH and salival flow with the use of fixed orthodontic appliances in patients attended in the Dental Care Private Clinic - Lima, 2018” | es_ES |
| dc.type | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| renati.advisor.dni | 10724066 | |
| renati.advisor.orcid | https://orcid.org/0000-0003-2925-8630 | |
| renati.author.dni | 71384549 | |
| renati.discipline | 911026 | |
| renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | |
| renati.type | https://purl.org/pe-repo/renati/type#tesis | |
| thesis.degree.discipline | Odontología | es_ES |
| thesis.degree.grantor | Universidad Privada Norbert Wiener. Facultad de Ciencias de la Salud | es_ES |
| thesis.degree.level | Título Profesional | es_ES |
| thesis.degree.name | Cirujano Dentista | es_ES |

