Efficacy of hypothermic perfusion machine compared to cold storage in reducing the risk of developing delayed graft function in cadaveric donor renal transplantation
| dc.contributor.advisor | Arevalo Marcos, Rodolfo Amado | |
| dc.contributor.author | Orozco Espinoza, Katherine Thalia | |
| dc.contributor.author | Salvador Ramirez, Karla Stefany | |
| dc.date.accessioned | 2020-09-02T18:21:56Z | |
| dc.date.available | 2020-09-02T18:21:56Z | |
| dc.date.issued | 2020-02-01 | |
| dc.description.abstract | Objective: Systematize the evidence on the hypothermic perfusion machine compared to cold storage to reduce the risk of developing delayed graft function in deceased donor kidney transplantation. Material and Methods: Retrospective and observational systematic review subject to critical reading and using the GRADE system as an evaluation tool to identify the quality of scientific evidence published in the following information sources Scielo, Elsevier, PubMed and Epistemonikos. Of the 10 articles reviewed systematically, 100% of high quality as described below: 90% of high quality as described below: 50% (n= 5/10) are meta-analyses, 20% (n= 2/ 10) is a systematic review and 20% (n= 2/10) are randomized controlled trials of moderate quality. 10% (n= 1/10) is a cohort study and They belong to the countries of China (20%), Australia (10%), England (10%), Spain (10%), Canada (10%), Brazil (10%), Belgium (10%), Netherlands (10%). %) and the United States (10%). Results: 100% (n=10/10) indicate that the hypothermic perfusion machine is more effective than cold storage in reducing the risk of developing delayed graft function in kidney transplant from a deceased donor. Conclusion: The hypothermic perfusion machine is more effective than cold storage in reducing the risk of developing delayed graft function in deceased donor kidney transplantation. | en_US |
| dc.description.abstract | Objetivo: Sistematizar las evidencias sobre la a máquina de perfusión hipotérmica comparada con almacenamiento en frio para la disminución del riesgo de desarrollar la función retardada del injerto en trasplante renal de donante fallecido. Material y Métodos: Revisión sistemática retrospectiva y observacional sujetos a lectura crítica y usando como herramienta de evaluación el sistema GRADE para la identificación de la calidad de las evidencias científicas publicadas en las siguientes fuentes de información Scielo, Elsevier, PubMed y Epistemonikos. De los 10 artículos revisados sistemáticamente el 100% de alta calidad como se describe a continuación: el 90% de alta calidad como se describe a continuación: el 50% (n= 5/10) son metaanálisis, 20% (n= 2/10) es revisión sistemática y el 20% (n= 2/10) son ensayos controlado aleatorizado y de moderada calidad 10% (n= 1/10) es estudio de cohorte y pertenecen a los países de China (20%), Australia (10%), Inglaterra (10%), España (10%), Canadá (10%), Brasil (10%), Bélgica (10%) Paises Bajos (10%) y Estados Unidos (10%). Resultados: El 100% (n=10/10) señalan que la máquina de perfusión hipotérmica es más eficaz que el almacenamiento en frio para la disminución del riesgo de desarrollar la función retardada del injerto en trasplante renal de donante fallecido. Conclusión: La máquina de perfusión hipotérmica es más eficaz que el almacenamiento en frio para la disminución del riesgo de desarrollar la función retardada del injerto en trasplante renal de donante fallecido. | es_ES |
| dc.description.researcharea | Salud, enfermedad y ambiente | |
| dc.format | application/pdf | |
| dc.identifier.uri | https://hdl.handle.net/20.500.13053/3810 | |
| dc.language.iso | spa | es_ES |
| dc.language.iso | spa | |
| dc.publisher | Universidad Privada Norbert Wiener | es_ES |
| dc.publisher.country | PE | es_ES |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.source | Repositorio Institucional de la Universidad Privada Norbert Wiener | es_ES |
| dc.subject | Eficacia | es_ES |
| dc.subject | Trasplante de Riñón | es_ES |
| dc.subject | Funcionamiento Retardado del Injerto | es_ES |
| dc.subject | Periodo Perioperatorio | es_ES |
| dc.subject | Perfusión | es_ES |
| dc.subject | Kidney Transplantation | es_ES |
| dc.subject | Delayed Graft Function | es_ES |
| dc.subject | Perioperative Period | es_ES |
| dc.subject | Perfusion | es_ES |
| dc.subject | Efficacy | es_ES |
| dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.03.03 | |
| dc.subject.ods | ODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades | |
| dc.title | Efficacy of hypothermic perfusion machine compared to cold storage in reducing the risk of developing delayed graft function in cadaveric donor renal transplantation | en_US |
| dc.title | Eficacia de la máquina de perfusión hipotérmica comparada con almacenamiento en frio para la disminución del riesgo de desarrollar la función retardada del injerto en trasplante renal de donante cadavérico | es_ES |
| dc.title.alternative | Efficacy of the hypothermic perfusion machine compared to cold storage for the reduction of the risk of developing delayed graft function in cadave donor kidney transplantation | es_ES |
| dc.type | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| renati.advisor.dni | 46370194 | |
| renati.advisor.orcid | https://orcid.org/0000-0002-4633-2997 | |
| renati.author.dni | 74021186 | |
| renati.author.dni | 70460389 | |
| renati.discipline | 913589 | |
| renati.juror | Uturunco Vera, Milagros Lizbeth | |
| renati.juror | Palomino Taquire, Rewards | |
| renati.juror | Basurto Santillan, Ivan Javier | |
| renati.level | https://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad | |
| renati.type | https://purl.org/pe-repo/renati/type#trabajoAcademico | |
| thesis.degree.discipline | Segunda Especialidad en Enfermería en Nefrología | es_ES |
| thesis.degree.grantor | Universidad Privada Norbert Wiener. Facultad de Ciencias de la Salud | es_ES |
| thesis.degree.level | Título de Segunda Especialidad | es_ES |
| thesis.degree.name | Especialista en Enfermería en Nefrología | es_ES |