Efficacy of hypothermic perfusion machine compared to cold storage in reducing the risk of developing delayed graft function in cadaveric donor renal transplantation

dc.contributor.advisorArevalo Marcos, Rodolfo Amado
dc.contributor.authorOrozco Espinoza, Katherine Thalia
dc.contributor.authorSalvador Ramirez, Karla Stefany
dc.date.accessioned2020-09-02T18:21:56Z
dc.date.available2020-09-02T18:21:56Z
dc.date.issued2020-02-01
dc.description.abstractObjective: Systematize the evidence on the hypothermic perfusion machine compared to cold storage to reduce the risk of developing delayed graft function in deceased donor kidney transplantation. Material and Methods: Retrospective and observational systematic review subject to critical reading and using the GRADE system as an evaluation tool to identify the quality of scientific evidence published in the following information sources Scielo, Elsevier, PubMed and Epistemonikos. Of the 10 articles reviewed systematically, 100% of high quality as described below: 90% of high quality as described below: 50% (n= 5/10) are meta-analyses, 20% (n= 2/ 10) is a systematic review and 20% (n= 2/10) are randomized controlled trials of moderate quality. 10% (n= 1/10) is a cohort study and They belong to the countries of China (20%), Australia (10%), England (10%), Spain (10%), Canada (10%), Brazil (10%), Belgium (10%), Netherlands (10%). %) and the United States (10%). Results: 100% (n=10/10) indicate that the hypothermic perfusion machine is more effective than cold storage in reducing the risk of developing delayed graft function in kidney transplant from a deceased donor. Conclusion: The hypothermic perfusion machine is more effective than cold storage in reducing the risk of developing delayed graft function in deceased donor kidney transplantation.en_US
dc.description.abstractObjetivo: Sistematizar las evidencias sobre la a máquina de perfusión hipotérmica comparada con almacenamiento en frio para la disminución del riesgo de desarrollar la función retardada del injerto en trasplante renal de donante fallecido. Material y Métodos: Revisión sistemática retrospectiva y observacional sujetos a lectura crítica y usando como herramienta de evaluación el sistema GRADE para la identificación de la calidad de las evidencias científicas publicadas en las siguientes fuentes de información Scielo, Elsevier, PubMed y Epistemonikos. De los 10 artículos revisados sistemáticamente el 100% de alta calidad como se describe a continuación: el 90% de alta calidad como se describe a continuación: el 50% (n= 5/10) son metaanálisis, 20% (n= 2/10) es revisión sistemática y el 20% (n= 2/10) son ensayos controlado aleatorizado y de moderada calidad 10% (n= 1/10) es estudio de cohorte y pertenecen a los países de China (20%), Australia (10%), Inglaterra (10%), España (10%), Canadá (10%), Brasil (10%), Bélgica (10%) Paises Bajos (10%) y Estados Unidos (10%). Resultados: El 100% (n=10/10) señalan que la máquina de perfusión hipotérmica es más eficaz que el almacenamiento en frio para la disminución del riesgo de desarrollar la función retardada del injerto en trasplante renal de donante fallecido. Conclusión: La máquina de perfusión hipotérmica es más eficaz que el almacenamiento en frio para la disminución del riesgo de desarrollar la función retardada del injerto en trasplante renal de donante fallecido.es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/3810
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectEficaciaes_ES
dc.subjectTrasplante de Riñónes_ES
dc.subjectFuncionamiento Retardado del Injertoes_ES
dc.subjectPeriodo Perioperatorioes_ES
dc.subjectPerfusiónes_ES
dc.subjectKidney Transplantationes_ES
dc.subjectDelayed Graft Functiones_ES
dc.subjectPerioperative Periodes_ES
dc.subjectPerfusiones_ES
dc.subjectEfficacyes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.03.03
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleEfficacy of hypothermic perfusion machine compared to cold storage in reducing the risk of developing delayed graft function in cadaveric donor renal transplantationen_US
dc.titleEficacia de la máquina de perfusión hipotérmica comparada con almacenamiento en frio para la disminución del riesgo de desarrollar la función retardada del injerto en trasplante renal de donante cadavéricoes_ES
dc.title.alternativeEfficacy of the hypothermic perfusion machine compared to cold storage for the reduction of the risk of developing delayed graft function in cadave donor kidney transplantationes_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni46370194
renati.advisor.orcidhttps://orcid.org/0000-0002-4633-2997
renati.author.dni74021186
renati.author.dni70460389
renati.discipline913589
renati.jurorUturunco Vera, Milagros Lizbeth
renati.jurorPalomino Taquire, Rewards
renati.jurorBasurto Santillan, Ivan Javier
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#trabajoAcademico
thesis.degree.disciplineSegunda Especialidad en Enfermería en Nefrologíaes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista en Enfermería en Nefrologíaes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
T061_74021186_70460389_S.pdf
Tamaño:
454.04 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones