In vitro evaluation of resistance to bending on three types of poles fiberglass of different brands, refor post (ángelus), fiber post (maquira) and medical micro (simplex), Lima 2022

dc.contributor.advisorRojas Ortega, Raúl Antonio
dc.contributor.authorVásquez Melgarejo, Leidy
dc.date.accessioned2023-11-17T15:12:36Z
dc.date.available2023-11-17T15:12:36Z
dc.date.issued2023-10-03
dc.description.abstractThe aim of this research was to compare the flexural strength of three brands of fiberglass posts: Fiber Post (Maquira), Refor Post (Ángelus), and Micro Medica (Simplex). An in vitro, comparative, prospective, and cross-sectional study was conducted with 30 fiberglass posts from three brands: Fiber Post (Maquira), Refor Post (Ángelus), and Micro Medica (Simplex), divided into three subgroups, each consisting of 10 fiberglass posts. Flexural strength was determined using a universal testing machine. Numerical values were collected using a data collection form, and the data was analyzed using the SPSS version 22.0 statistical software. The results showed that the flexural strength of the Refor Post fiberglass post had an average of 887.49 MPa, followed by Fiber Post and Micro Medica with averages of 798.91 MPa and 607.75 MPa, respectively. In conclusion, the Refor Post fiberglass post showed superior resistance compared to the Fiber Post and Micro Medica brands.en_US
dc.description.abstractLa finalidad de la presente. investigación. tiene como objetivo el comparar. la resistencia. a la flexión de tres tipos de marcas de poste de fibra. de vidrio, Fiber Post (Maquira), Refor Post (Ángelus) y Micro Medica (Simplex). Se realizó un estudio in vitro, comparativo, prospectivo y transversal, estuvo compuesto por 30 postes. de. FV de tres tipos de marcas, Fiber Post (Maquira), Refor Post (Ángelus) y Micro Medica (Simplex), dividiéndose en tres sub grupos y cada uno compuesto por n=10 postes de fibra. de. vidrio. Se determinó la resistencia a la flexión por medio de una maquina universal. Se recolectaron los valores numéricos mediante una. ficha. de recolección. de datos. Se evaluaron las cifras y valores con un paquete. Estadístico. SPSS versión. 22.0. Los resultados. de resistencia. a la flexión. del poste de FV. Refor Post presentan un promedio de 887.49 Mpa, seguida de Fiber Post y Micro médica con promedios de 798.91 Mpa y 607.75 Mpa respectivamente. En conclusión, el poste. de. FV Refor Post mostró superioridad en la resistencia a comparación de la marca Fiber Post y Micro médicaes_ES
dc.description.researchareaSalud y Bienestar
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/9893
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectResistencia a la flexiónes_ES
dc.subjectPoste de fibra de vidrioes_ES
dc.subjectMateriales dentaleses_ES
dc.subjectFlexural strengthes_ES
dc.subjectFiberglass postes_ES
dc.subjectDental materialses_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleIn vitro evaluation of resistance to bending on three types of poles fiberglass of different brands, refor post (ángelus), fiber post (maquira) and medical micro (simplex), Lima 2022en_US
dc.titleEvaluación in vitro de la resistencia a la flexión en tres tipos de postes de fibra de vidrio de diferentes marcas: Refor Post (Ángelus), Fiber Post (Maquira) y Micro Médica (Simplex), Lima 2022es_ES
dc.title.alternativeIn vitro evaluation of resistance to bending on three types of poles fiberglass of different brands, refor post (ángelus), fiber post (maquira) and medical micro (simplex), Lima 2022es_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni07761772
renati.advisor.orcidhttps://orcid.org/0000-0002-0165-7501
renati.author.dni77689277
renati.discipline911026
renati.jurorSotomayor León, Gino Aurelio
renati.jurorGuevara Sotomayor, Juan César
renati.jurorLujan Larreategui, Haydeé Giovanna
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineOdontologíaes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo Profesionales_ES
thesis.degree.nameCirujano Dentistaes_ES

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
T061_77689277_T.pdf
Tamaño:
1.74 MB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
FORM_77689277_T.pdf
Tamaño:
177.78 KB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
TURNITIN_77689277_T.pdf
Tamaño:
788.21 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones