Fatigue resistance of exact fiberglass posts - angelus, white post, angelus reforpost, in vitro study – Lima 2020.
| dc.contributor.advisor | Chanamé Marín, Ann Rosemary | |
| dc.contributor.author | Dilas Teran, Santos | |
| dc.date.accessioned | 2021-06-02T21:39:08Z | |
| dc.date.available | 2021-06-02T21:39:08Z | |
| dc.date.issued | 2020-12-19 | |
| dc.description.abstract | The objective of this study was to determine the best fatigue resistance of the fiberglass posts Exacto - Angelus, White Post, and Reforpost by Ángelus in an in vitro study. Each post was evaluated using an optical microscope and measured in length and diameter with a 200 mm digital vernier caliper. A total of 60 fiberglass posts were divided into three groups: Group 1: Exacto – Angelus, Group 2: White Post, and Group 3: Reforpost by Angelus. These were then subjected to a linear cyclic load fatigue machine HTL Certificate – 021 with a 1.6 mm diameter punch, a free span of 7 mm, applying a load at 90° and a frequency of 5.84 Hz at 20 N. The results showed that the Exacto – Angelus fiberglass post achieved an average fatigue resistance of 38,692.5 cycles with a mean time of 110.55 minutes, while the White Post had an average fatigue resistance of 31,921.25 cycles with a time of 91.225 minutes, and the Reforpost by Angelus had an average fatigue resistance of 25,970 cycles at 74.2 minutes. It was concluded that the Exacto – Angelus post showed the highest fatigue resistance time. | en_US |
| dc.description.abstract | El objetivo del presente estudio fue determinar la mejor resistencia a la fatiga de los postes de fibra de vidrio Exacto - Angelus, White Post, Reforpost de Ángelus, en un estudio en vitro. Cada poste fue valorado empleando microscopio óptico y medido en longitud y diámetro con un calibrador vernier digital de 200 mm, luego se dividieron a 60 postes de fibra de vidrios, en tres grupos, grupo 1: Exacto – Ángelus, grupo 2: White post y grupo 3: Reforpost de Ángelus, luego fueron sometidos a la maquina fatigadora de carga cíclica lineal HTL certifícate – 021 con punzón de 1.6 mm de diámetro, longitud libre entre apoyos 7 mm, aplicando una carga a 90 ° y frecuencia de 5.84 HZ a 20 N. Obteniendo: el poste fibra de vidrio Exacto – Ángelus obtuvo una resistencia media a la fatiga de 38692.5 ciclos con un el tiempo medio de 110.55 minutos, para los White post se reporta una resistencia media a la fatiga de 31921.25 cuyo tiempo fue 91.225 minutos y para Reforpost de Ángelus una resistencia media a la fatiga de 25970 ciclos respectivamente, a 74.2 minutos. Se concluye que el poste Exacto – Ángelus, es el que presenta mayor tiempo de resistencia a la fatiga. | es_ES |
| dc.description.researcharea | Salud, enfermedad y ambiente | |
| dc.format | application/pdf | |
| dc.identifier.uri | https://hdl.handle.net/20.500.13053/4663 | |
| dc.language.iso | spa | es_ES |
| dc.language.iso | spa | |
| dc.publisher | Universidad Privada Norbert Wiener | es_ES |
| dc.publisher.country | PE | es_ES |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.source | Repositorio Institucional de la Universidad Privada Norbert Wiener | es_ES |
| dc.subject | Resistencia a la fatiga | es_ES |
| dc.subject | Postes de fibra de vidrio | es_ES |
| dc.subject | Carga cíclica | es_ES |
| dc.subject | Fatigue resistance | es_ES |
| dc.subject | Fiberglass posts | es_ES |
| dc.subject | Cyclic load | es_ES |
| dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.14 | |
| dc.subject.ods | ODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades | |
| dc.title | Fatigue resistance of exact fiberglass posts - angelus, white post, angelus reforpost, in vitro study – Lima 2020. | en_US |
| dc.title | Resistencia a la fatiga de los postes de fibra de vidrio Exacto - Angelus, White Post, Reforpost de Angelus, estudio in vitro – Lima 2020. | es_ES |
| dc.title.alternative | Fatigue resistance of exact fiberglass posts - angelus, white post, angelus reforpost, in vitro study – Lima 2020. | es_ES |
| dc.type | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| renati.advisor.dni | 42767874 | |
| renati.advisor.orcid | https://orcid.org/0000-0002-5038-4116 | |
| renati.author.dni | 10487075 | |
| renati.discipline | 911026 | |
| renati.juror | Gómez Carrión, Christian Esteban | |
| renati.juror | Girano Castaños, Jorge Alberto | |
| renati.juror | Llerena Meza, Verónica | |
| renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | |
| renati.type | https://purl.org/pe-repo/renati/type#tesis | |
| thesis.degree.discipline | Odontología | es_ES |
| thesis.degree.grantor | Universidad Privada Norbert Wiener. Facultad de Ciencias de la Salud | es_ES |
| thesis.degree.level | Título Profesional | es_ES |
| thesis.degree.name | Cirujano Dentista | es_ES |