dc.description.abstractCandida albicans identification is performed with the germ tube test using human serum, which, despite being accessible, is not biosecure. Various researchers have conducted this test using egg albumin with satisfactory results but did not measure its performance. The aim of this study was to evaluate the performance of the germ tube test with egg albumin in identifying Candida albicans. This was a quantitative, observational, analytical, cross-sectional study conducted at the Norbert Wiener University Laboratory, following INS protocols. The germ tube test was performed using egg albumin from Gallus gallus domesticus, employing 118 Candida albicans strains and 12 non-Candida albicans strains. Sensitivity, specificity, false positives, false negatives, and efficiency were: 95.8%, 100%, 0%, 4.2%, and 96.2%, respectively. The Kappa index was 0.81, indicating high agreement with the reference method. Following SEIMC criteria, it was concluded that the test using egg albumin is acceptable for identifying Candida albicans and is an economical, accessible, and, above all, safe medium for laboratory personnel.en_US
dc.description.abstractLa identificación de Candida albicans se realiza con la prueba del tubo germinativo con suero humano, que a pesar de ser un medio accesible no es bioseguro. Diversos investigadores realizaron esta prueba con albumina de huevo encontrando resultados satisfactorios, sin embargo no midieron su rendimiento. El objetivo del estudio fue evaluar el rendimiento de la prueba del tubo germinativo con albumina de huevo en la identificación de Candida albicans. Se ejecutó una investigación cuantitativa, observacional, analítica de corte transversal en el laboratorio de la Universidad Norbert Wiener, siguiendo el protocolo del INS, la prueba del tubo germinativo se realizó con albúmina de huevo de Gallus gallus domesticus, empleando 118 cepas de Candida albicans y 12 cepas de Candida no albicans. La sensibilidad, la especificidad, falsos positivos, falsos negativos y eficiencia fueron: 95.8%, 100%, 0%, 4.2% y de 96.2% respectivamente. El índice Kappa fue de 0.81 calificándola como altamente concordante al método de referencia. Siguiendo los criterios de la SEIMC, se concluye que el rendimiento de la prueba con albumina de huevo es aceptable para la identificación de Candida albicans, siendo además un medio económico, accesible y sobretodo seguro para el personal de laboratorio.es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/3762
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectCandida albicanses_ES
dc.subjectCandida albicanses_ES
dc.subjectCentro Germinales_ES
dc.subjectGerminal Centeres_ES
dc.subjectIdentificaciónes_ES
dc.subjectAlbúmina Sérica Humanaes_ES
dc.subjectSerum Albumin, Humanes_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.06.02
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleEgg Albumin Germ Tube Test Performance in Identifying Candida Albicans, 2020en_US
dc.titleRendimiento de la prueba del tubo germinativo con albumina de huevo en la identificación de Candida Albicans, 2020.es_ES
dc.title.alternativeEgg Albumin Germ Tube Test Performance in Identifying Candida Albicans, 2020.es_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.cext 
renati.advisor.dni06134815
renati.advisor.orcidhttps://orcid.org/0000-0002-5803-9659
renati.advisor.pasaporte 
renati.author.cext 
renati.author.dni48311605
renati.author.dni43691826
renati.author.pasaporte 
renati.discipline915126
renati.jurorBenites Azabache, Juan Carlos
renati.jurorSandoval Vegas, Miguel Hernán
renati.jurorHuamán Cárdenas, Victor Raúl
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineTecnología Médica en Laboratorio Clínico y Anatomía Patológicaes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo Profesionales_ES
thesis.degree.nameLicenciada en Tecnología Médica en Laboratorio Clínico y Anatomía Patológicaes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
T061_48311605_43691826_T.pdf
Tamaño:
2.65 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: