Effectiveness of high-level disinfection of medical devices to prevent infections in patients undergoing minimally invasive procedures

dc.contributor.advisorGlenni Garay, Zarely Zabeli
dc.contributor.authorNeyra Gil, Lourdes Soraya
dc.contributor.authorCárdenas Cossio, Gisela Coralí
dc.date.accessioned2019-05-16T17:18:18Z
dc.date.available2019-05-16T17:18:18Z
dc.date.issued2019-01-06
dc.description.abstractObjective: Systematize the evidence on the effectiveness of high-level disinfection in medical devices to prevent infections in patients undergoing minimally invasive procedures. Material and Methods: Systematic review that summarizes the results of various investigations, identifying what is most relevant to answer specific questions. The search has been limited to articles with full text that have been critically read, using the GRADE evaluation to assign their level of evidence. Results: In the final selection, 05 articles were chosen, finding that 40% (04) correspond to Brazil, Peru and Mexico and 10% (01) Asia (India). These are mostly experimental studies (10%), descriptive case series type (20%), systematic reviews (10%), controlled clinical trials (10%). 100% of the articles state that high-level disinfection (HLD) does not ensure the elimination of the most resistant microorganisms such as endospores and some mycobacterium, such as microorganisms of the Coccidia subclass such as M. Masiliense, so this process is not considered effective in preventing infections in minimally invasive procedures. Conclusions: High-level disinfection is not effective in medical devices to prevent infections in patients undergoing minimally invasive procedures.en_US
dc.description.abstractObjetivo: Sistematizar la evidencia sobre la efectividad de la desinfección de alto nivel en los dispositivos médicos para prevenir infecciones en pacientes sometidos a procedimientos mínimamente invasivos. Material y Métodos: Revisión sistemática que resume los resultados de diversas investigaciones, identificando lo más relevante para responder preguntas específicas. La búsqueda se ha limitado a artículos con texto completo sometidos a una lectura crítica, utilizando la evaluación GRADE para asignar su grado de evidencia. Resultados: En la selección definitiva se eligieron 05 artículos, encontrando que el 40% (04) corresponden a Brasil, Perú y México y 10%(01) Asia (India). Estos en su mayoría son estudios experimentales (10%), descriptivo tipo serie de casos (20%), revisiones sistemáticas (10%), ensayo clínico controlado (10%). El 100% de los artículos afirma que la desinfección de alto nivel (DAN) no asegura la eliminación de los microorganismos más resistentes como son las endosporas y algunas mico bacterias, como los microorganismos de la subclase Coccidia como M. Masiliense, por lo que este proceso no se considera efectivo en la prevención de infecciones en los procedimientos mínimamente invasivos. Conclusiones: La desinfección de alto nivel, no es efectivo en los dispositivos médicos para prevenir infecciones en pacientes sometidos a procedimientos mínimamente invasivoses_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/2836
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectEquipos y Suministroses_ES
dc.subjectControl de Infeccioneses_ES
dc.subjectProcedimientos Quirúrgicos Mínimamente Invasivoses_ES
dc.subjectEquipment and Supplieses_ES
dc.subjectInfection Controles_ES
dc.subjectMinimally Invasive Surgical Procedureses_ES
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#3.03.03
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleEffectiveness of high-level disinfection of medical devices to prevent infections in patients undergoing minimally invasive proceduresen_US
dc.titleEfectividad de la desinfección de alto nivel en los dispositivos médicos para prevenir infecciones en pacientes sometidos a procedimientos mínimamente invasivoses_ES
dc.title.alternativeEFFECTIVENESS OF HIGH-LEVEL DISINFECTION IN MEDICAL DEVICES TO PREVENT INFECTION IN PATIENTS SUBMITTED TO MINIMALLY INVASIVE PROCEDURESes_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni43514778
renati.author.dni22300543
renati.discipline021209
renati.jurorCalsin Pacompia, Wilmer
renati.jurorArévalo Marco, Rodolfo Amado
renati.jurorPalomino Carrión, Ruby Cecilia
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#trabajoAcademico
thesis.degree.disciplineSegunda Especialidad de Gestión en Central de Esterilizaciónes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista de Gestión en Central de Esterilizaciónes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
TRABAJO ACADÉMICO Cárdenas Gisela - Neyra Lourdes.pdf
Tamaño:
916.63 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones