Effectiveness of Ethylene Oxide Sterilization in Narrow Lumen Thermosensitive Medical Devices

dc.contributor.advisorMori Castro, Jaime Alberto
dc.contributor.authorHuamán Allca, Sofía Felipa
dc.contributor.authorRomán Obregón, Carmen Rosa
dc.date.accessioned2022-01-14T16:51:26Z
dc.date.available2022-01-14T16:51:26Z
dc.date.issued2021-09-05
dc.description.abstractObjective: To systematize evidence on the effectiveness of ethylene oxide sterilization processes for medical devices with narrow lumens. Material and method: This research has a quantitative approach, and the design is a systematic review. A total of 10 scientific articles were reviewed, which were subjected to critical reading and analyzed using the Grade system to identify the level of quality of the evidence. Results: Of the 10 articles analyzed, 100% (n=10/10) indicate that the ethylene oxide sterilization method for thermosensitive medical devices with lumens or hollow structures is effective due to its strong bactericidal, viricidal, and fungicidal properties, and above all, its high penetrating power and compatibility with all materials. Conclusions: The scientific evidence allows us to conclude that ethylene oxide as a sterilizing agent is effective for devices with narrow lumens due to its high penetrability, and it does not damage or deform the material being sterilized.en_US
dc.description.abstractObjetivo: Sistematizar evidencias en la efectividad de los procesos de esterilización por óxido de etileno para dispositivo médico de lumen angosto. Material y método: El trabajo de investigación es del tipo de enfoque cuantitativo, el diseño es una Revisión sistemática. Se revisaron un total de 10 artículos científicos, los cuales fueron sometidos a lectura crítica y analizados con el sistema grade, para identificar el nivel de calidad de la evidencia. Resultados: Los 10 artículos que fueron analizados, el 100% (n=10/10) indican que el método de esterilización por óxidos de etileno en el dispositivo médico termosensible con lumen o estructura hueca es eficaz, por el gran poder bactericida, viricida, fungicida, y por sobre todo su gran poder penetrante y de ser muy compatibles con todos los materiales. Conclusiones: la evidencia científica nos permite concluir que el agente óxido de etileno como esterilizante, es efectivo en dispositivos con lúmenes estrechos, por su alta penetrabilidad, además no daña ni deforma el material sometido a esterilizar.es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/5345
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectEfectividades_ES
dc.subjectÓxido de Etilenoes_ES
dc.subjectEquipos y Suministroses_ES
dc.subjectEffectivenesses_ES
dc.subjectEthylene Oxidees_ES
dc.subjectEquipment and Supplieses_ES
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#3.03.03
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleEffectiveness of Ethylene Oxide Sterilization in Narrow Lumen Thermosensitive Medical Devicesen_US
dc.titleEfectividad de la esterilización por óxido de etileno en dispositivos médicos termosensibles con lumen angostoes_ES
dc.title.alternative“Effectiveness of Ethylene Oxide Sterilization in Narrow Lumen Thermosensitive Medical Devices“es_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.cext 
renati.advisor.dni07537045
renati.advisor.orcidhttps://orcid.org/0000-0003-2570-0401
renati.advisor.pasaporte 
renati.author.cext 
renati.author.dni09789962
renati.author.dni10636232
renati.author.pasaporte 
renati.discipline021209
renati.jurorGonzales Saldaña, Susan Haydee
renati.jurorUturunco Vera, Milagros Lizbeth
renati.jurorFernandez Rengifo, Werther Fernando
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#trabajoAcademico
thesis.degree.disciplineSegunda Especialidad de Gestión en Central de Esterilizaciónes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista de Gestión en Central de Esterilizaciónes_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
T061_09789962_10636232_S.pdf
Tamaño:
370.84 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones