Quality Parameters of Platelet Concentrates Obtained by Leukocyte-Platelet Layer at Alberto Sabogal Sologuren Hospital, 2018

dc.contributor.advisorParedes Arrascue, Jose Antonio
dc.contributor.authorAlvarez Trujillo, Teresa
dc.contributor.authorCueva Tolentino, Magdalena Macaria
dc.date.accessioned2018-08-16T15:03:14Z
dc.date.available2018-08-16T15:03:14Z
dc.date.issued2018-06-19
dc.description.abstractThe objective was to determine the compliance with quality parameters of platelet concentrates obtained by the leukocyte platelet layer method." Material and Methods: This is an observational, descriptive, cross-sectional study determining the compliance with quality parameters such as pH, volume, swirl phenomenon, storage temperature, platelet count, residual leukocyte count, and microbiological study of platelet concentrates. Random sampling with a 95% confidence level resulted in a sample size of 384 platelet concentrates. Results: 50.8% of the platelet concentrates met the optimal platelet count, and other parameters were met as follows: 90.1% for plasma volume, 99.5% for required pH, 97.1% for the swirl phenomenon, and 100% for residual leukocyte count and microbiological control. Conclusions and Recommendations: It was concluded that platelet concentrates meet quality parameters for plasma volume, pH, residual leukocyte count, swirl phenomenon, and microbiological control. The quality parameter not meeting the established requirement was platelet count. Therefore, it is recommended to monitor and evaluate compliance with quality standards by standardizing the processes in the extraction, production, and storage of platelet concentrates.en_US
dc.description.abstractLa investigación tuvo como objetivo determinar el cumplimiento de los parámetros de calidad de los concentrados plaquetarios obtenidos por capa leucoplaquetaria. Material y Método: es un estudio observacional descriptivo de corte transversal que determina el cumplimiento de los parámetros de calidad: pH, volumen, fenómeno de remolino, temperatura de almacenamiento, recuento plaquetario, recuento residual de leucocitos y estudio microbiológico de los concentrados plaquetarios. El muestreo fue aleatorio con un grado de confianza de 95%, obteniéndose un tamaño muestral de 384 concentrados plaquetarios. Resultados: se encontró que el 50.8% de los concentrados plaquetarios cumplen con un recuento plaquetario óptimo, los parámetros restantes cumplieron en 90.1% para volumen plasmático, 99.5% en pH requerido, 97.1% en fenómeno de remolino, y 100% en recuento residual de leucocitos y control microbiológico. Conclusiones y Recomendaciones: se concluye que los concentrados plaquetarios cumplen con los parámetros de calidad en volumen plasmático, pH, recuento residual de leucocitos, fenómeno de remolino, control microbiológico y el parámetro de calidad que no cumple con el requisito de calidad establecido es el recuento de plaquetas. Por tanto, se recomienda supervisar y evaluar el cumplimiento de las normas de calidad estandarizando los procesos en la extracción, obtención y almacenamiento de los concentrados plaquetarios.es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/1851
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectControl de Calidades_ES
dc.subjectQuality Controles_ES
dc.subjectControl de Calidades_ES
dc.subjectQuality Controles_ES
dc.subjectCapa Leucocitaria de la Sangrees_ES
dc.subjectBlood Buffy Coates_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.06
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleQuality Parameters of Platelet Concentrates Obtained by Leukocyte-Platelet Layer at Alberto Sabogal Sologuren Hospital, 2018en_US
dc.titleParámetros de calidad de los concentrados plaquetarios obtenidos por capa leucoplaquetaria en el Hospital Alberto Sabogal Sologuren, 2018es_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.cext 
renati.advisor.dni06144113
renati.advisor.orcid 
renati.advisor.pasaporte 
renati.author.cext 
renati.author.dni 
renati.author.pasaporte 
renati.discipline912439
renati.jurorArispe Alburqueque, Claudia Milagros
renati.jurorSandoval Vegas, Miguel Hernán
renati.jurorPalacios Butrón, Fernando Sarco
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineSegunda Especialidad en Hemoterapia y Banco de Sangrees_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista en Hemoterapia y Banco de Sangrees_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
ESPECIALIDAD - Alvarez Trujillo, Teresa.pdf
Tamaño:
2.26 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: