Comparison of dimensional changes and roughness between two marks of conventional alginates and two marks of alginates with silicone particles according to elapsed time

dc.contributor.advisorMorante Maturana, Sara Angelica
dc.contributor.authorFlorez Gonzales, Maribel
dc.date.accessioned2024-01-03T20:37:38Z
dc.date.available2024-01-03T20:37:38Z
dc.date.issued2023-10-13
dc.description.abstractThe objective of this study was to compare the dimensional change and roughness between two brands of conventional alginates and two brands of silicone particle alginates over time. The methodology used in this study was experimental, prospective, longitudinal, and quantitative. The sample consisted of 60 models of impressions taken with conventional alginates Zetalgin and Hygedent and silicone particle alginates Neocolloid and Hygedent 100. For each group of alginates, 5, 15, and 30 minutes post-impression were considered for the corresponding pouring. A master model was used for all impressions to achieve homogeneous samples. After the impressions were taken, they were measured using a digital caliper for greater accuracy and a digital profilometer. A data collection sheet was used as the instrument, employing the observation technique. The Shapiro-Wilk test was used, followed by the Mann-Whitney U test and Student's t-test to determine if there were differences in dimensional stability and roughness. The results showed that regarding dimensional changes over time, no significant differences were found at 5 and 15 minutes (p > 0.05), but significant differences were found at 30 minutes (p < 0.05). Regarding roughness over time, no significant differences were found at 5, 15, and 30 minutes (p > 0.05).en_US
dc.description.abstractEl presente estudio desarrollado, tuvo como objetivo comparar el cambio dimensional y rugosidad entre dos marcas de alginatos convencionales y dos marcas de alginatos con partículas de silicona según tiempo transcurrido. La metodología empleada en el estudio fue de tipo experimental, prospectiva, longitudinal y enfoque cuantitativo. La muestra estuvo conformada por 60 modelos de impresiones tomadas con alginatos convencionales Zetalgin e Hygedent y alginatos con partículas de silicona Neocolloid e Hygedent 100. En cada grupo de alginatos se consideró 5, 15 y 30 minutos respectivos post impresión para la realización del vaciado correspondiente. Se utilizó un modelo maestro para todas las impresiones y conseguir las muestras homogéneas respectivas. Luego las impresiones fueron retiradas para ser respectivamente medidas mediante la ayuda de un Pie de Rey digital para mayor exactitud y un rugosímetro digital. Como instrumento se utilizó una ficha de recolección de datos usando como técnica la observación. Se empleó la prueba de Shapiro-Wilk para luego mediante la prueba de U Mann-Whitney y T de Student determinar si existían diferencias en la estabilidad dimensional y rugosidad. En los resultados se halló respecto a los cambios dimensionales según el tiempo transcurrido, que a los 5 y 15 minutos no existen diferencias significativas (p>0.05), a los 30 minutos existe diferencias significativas (p<0.05); en cuanto a la rugosidad según el tiempo transcurrido, se aprecia que a los 5, 15 y 30 minutos no existen diferencias significativas (p>0.05).es_ES
dc.description.researchareaSalud y Bienestar
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/10150
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectCambio dimensionales_ES
dc.subjectRugosidades_ES
dc.subjectAlginatos convencionaleses_ES
dc.subjectDimensional changees_ES
dc.subjectRoughnesses_ES
dc.subjectConventional alginateses_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleComparison of dimensional changes and roughness between two marks of conventional alginates and two marks of alginates with silicone particles according to elapsed timeen_US
dc.titleComparación de cambios dimensionales y rugosidad entre dos marcas de alginatos convencionales y dos marcas de alginatos con partículas de silicona según tiempo transcurridoes_ES
dc.title.alternativeComparison of dimensional changes and roughness between two marks of conventional alginates and two marks of alginates with silicone particles according to elapsed timees_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni10138106
renati.advisor.orcidhttps://orcid.org/0000-0001-9715-728X
renati.author.dni43240131
renati.discipline911026
renati.jurorRojas Ortega, Raúl Antonio
renati.jurorGomez Carrion, Christian
renati.jurorMinaya Rondon, Omar
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineOdontologíaes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo Profesionales_ES
thesis.degree.nameCirujano Dentistaes_ES

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
T061_43240131_T.pdf
Tamaño:
3.15 MB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
FORM_43240131_T.pdf
Tamaño:
244.8 KB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
TURNITIN_43240131_T.pdf
Tamaño:
917.55 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones