Effectiveness of targeted noise reduction strategies to ameliorate stress on physiological systems in the neonatal intensive care unit
| dc.contributor.advisor | Uturunco Vera, Milagros Lizbeth | |
| dc.contributor.author | Zumaeta Becerril, Lleny | |
| dc.contributor.author | Vásquez Lévano, Severina Paola | |
| dc.date.accessioned | 2020-09-02T16:37:22Z | |
| dc.date.available | 2020-09-02T16:37:22Z | |
| dc.date.issued | 2020-01-25 | |
| dc.description.abstract | Objective: Systematize the evidence on the effectiveness of targeted noise reduction strategies to improve the stress of physiological systems in the neonatal intensive care unit. Material and Methods: The systematic review of 10 articles that had as their topic the effectiveness of strategies aimed at reducing noise to improve the stress of physiological systems, were found from the following databases: Pubmed, Epistemonikos, medline were analyzed according to the Grade scale to determine its strength and quality of evidence. Results: According to the study design, 30% systematic reviews, 30% randomized controlled trial, 20% quasi-experimental, 10% case-control group and 10% case-control group were found. Of the evidence found, it shows that 70% of the targeted strategies are effective and 30% could not demonstrate the effectiveness of the strategies due to the lower number of investigations. Conclusion: It was concluded that 7 of 10 evidence shows that there is effectiveness of the strategies in reducing noise reaching between 45 dB to 56.6 dB, and that 3 of 10 of the evidence could not demonstrate effectiveness of strategies due to the lower number of evidence. | en_US |
| dc.description.abstract | Objetivo: Sistematizar la evidencia sobre la efectividad de estrategias dirigidas en la reducción del ruido para mejorar el estrés de los sistemas fisiológicos en la unidad de cuidados intensivos neonatales. Material y Métodos: La revisión sistemática de 10 artículos que tuvieron como tema la efectividad de estrategias dirigidas en la reducción del ruido para mejorar el estrés de los sistemas fisiológicos, fueron hallados de las siguientes bases de datos: Pubmed, Epistemonikos, medline fueron analizados según la escala Grade para determinar su fuerza y calidad de evidencia. Resultados: De acuerdo al diseño de estudio se encontraron 30% revisiones sistemáticas, 30% ensayo controlado aleatorizado, 20% cuasi experimental, 10% Grupo de casos y controles y 10% de casos y controles. De las evidencias encontradas muestran que el 70% existe efectividad de estrategias dirigidas y 30% no se pudo demostrar efectividad de las estrategias debido a su menor número de investigaciones. Conclusión: Se concluyó que 7 de 10 evidencias muestran que hay efectividad de las estrategias en la reducción del ruido llegando entre 45 dB a 56,6 dB, y que 3 de 10 de las evidencias no se pudo demostrar efectividad de estrategias debido al menor número de evidencias. | es_ES |
| dc.description.researcharea | Salud, enfermedad y ambiente | |
| dc.format | application/pdf | |
| dc.identifier.uri | https://hdl.handle.net/20.500.13053/3807 | |
| dc.language.iso | spa | es_ES |
| dc.language.iso | spa | |
| dc.publisher | Universidad Privada Norbert Wiener | es_ES |
| dc.publisher.country | PE | es_ES |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.source | Repositorio Institucional de la Universidad Privada Norbert Wiener | es_ES |
| dc.subject | Efectividad | es_ES |
| dc.subject | Monitoreo del Ruido | es_ES |
| dc.subject | Estrés Fisiológico | es_ES |
| dc.subject | Unidades de Cuidado Intensivo Neonatal | es_ES |
| dc.subject | Effectiveness | es_ES |
| dc.subject | Noise Monitoring | es_ES |
| dc.subject | Stress, Physiological | es_ES |
| dc.subject | Intensive Care Units, Neonatal | es_ES |
| dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.03.03 | |
| dc.subject.ods | ODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades | |
| dc.title | Effectiveness of targeted noise reduction strategies to ameliorate stress on physiological systems in the neonatal intensive care unit | en_US |
| dc.title | Efectividad de estrategias dirigidas en la reducción del ruido para mejorar el estrés en los sistemas fisiológicos en la unidad de cuidados intensivos neonatales | es_ES |
| dc.title.alternative | Effectiveness of targeted noise reduction strategies to improve stress on physiological systems in the neonatal intensive care unit. | es_ES |
| dc.type | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| renati.advisor.dni | 44551282 | |
| renati.advisor.orcid | https://orcid.org/0000-0002-8482-1281 | |
| renati.author.dni | 40506675 | |
| renati.author.dni | 45831195 | |
| renati.discipline | 922159 | |
| renati.juror | Pretell Aguilar, Rosa Maria | |
| renati.juror | Canales Rimachi, Reyda Ismaela | |
| renati.juror | Zavaleta Gutierrez, Violeta Aidee | |
| renati.level | https://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad | |
| renati.type | https://purl.org/pe-repo/renati/type#trabajoAcademico | |
| thesis.degree.discipline | Segunda Especialidad en Enfermería en Cuidados Intensivos Neonatales | es_ES |
| thesis.degree.grantor | Universidad Privada Norbert Wiener. Facultad de Ciencias de la Salud | es_ES |
| thesis.degree.level | Título de Segunda Especialidad | es_ES |
| thesis.degree.name | Especialista en Enfermería en Cuidados Intensivos Neonatales | es_ES |

