Efficacy of single-use disposable medical devices that are reprocessed
| dc.contributor.advisor | Matta Solis, Hernán Hugo | |
| dc.contributor.author | Guzmán Alfaro, Henry Augusto | |
| dc.contributor.author | Arrunátegui Bernal, Marlene Yvette | |
| dc.date.accessioned | 2019-05-16T18:01:28Z | |
| dc.date.available | 2019-05-16T18:01:28Z | |
| dc.date.issued | 2019-01-06 | |
| dc.description.abstract | A descriptive observational study was carried out, the design was a systematic review, the data collection was done through a bibliographic review of international research articles whose main objective was to systematize the evidence on the effectiveness of single-use disposable medical devices. reprocessed. 10 studies published in scientific databases were reviewed. The selected articles underwent evaluation using the GRADE method, which made it possible to evaluate the quality of evidence and grade the strength of the recommendations. Of the 10 studies reviewed, 70% show that the reprocessing of single-use disposable medical devices is effective and safe in terms of sterilization and efficacy, therefore, they can be reused in procedures, 30% show that Reprocessing of single-use disposable medical devices is not effective and safe in terms of sterilization and efficacy. It is concluded that the academic work evidences and concludes in the largest proportion of the included studies that the reprocessing of single-use disposable medical devices is effective and safe, however, this must be accompanied by a correct sterilization process. that guarantees said use. | en_US |
| dc.description.abstract | Se realizó un estudio tipo observacional descriptivo, el diseño fue revisión sistemática, la recolección de datos se hizo a través de revisión bibliográfica de artículos de investigación internacional que tuvieron como objetivo principal sistematizar las evidencia sobre la eficacia de los dispositivos médicos descartables de un solo uso reprocesados. Se revisaron 10 estudios publicados en base de datos científicas. Los artículos seleccionados se sometieron a evaluación por método GRADE el cual permitió evaluar la calidad de evidencia y graduar la fuerza de las recomendaciones. De los 10 estudios revisados, el 70% evidencian que el reprocesamiento de los dispositivos médicos descartables de un solo uso es eficaz y seguro en términos de esterilización y eficacia, por lo tanto, se pueden reutilizar en los procedimientos, el 30% evidencian que el reprocesamiento de los dispositivos médicos descartables de un solo uso no es eficaz y seguro en términos de esterilización y eficacia. Se concluye que el trabajo académico, evidencia y concluye en la mayor proporción de los estudios incluidos, que el reprocesamiento de los dispositivos médicos descartables de un solo uso es eficaz y seguro, sin embargo, esta debe de ir acompañado de un correcto proceso de esterilización que garantice dicho uso. | es_ES |
| dc.description.researcharea | Salud, enfermedad y ambiente | |
| dc.format | application/pdf | |
| dc.identifier.uri | https://hdl.handle.net/20.500.13053/2839 | |
| dc.language.iso | spa | es_ES |
| dc.language.iso | spa | |
| dc.publisher | Universidad Privada Norbert Wiener | es_ES |
| dc.publisher.country | PE | es_ES |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.source | Repositorio Institucional de la Universidad Privada Norbert Wiener | es_ES |
| dc.subject | Equipos y Suministros de Hospitales | es_ES |
| dc.subject | Seguridad de Equipos | es_ES |
| dc.subject | Eficacia | es_ES |
| dc.subject | Equipment and Supplies, Hospital | es_ES |
| dc.subject | Equipment Safety | es_ES |
| dc.subject | Effectiveness | es_ES |
| dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#3.03.03 | |
| dc.subject.ods | ODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades | |
| dc.title | Efficacy of single-use disposable medical devices that are reprocessed | en_US |
| dc.title | Eficacia de los dispositivos médicos desechables de un solo uso reprocesados | es_ES |
| dc.title.alternative | EFFECTIVENESS OF DISPOSABLE MEDICAL DEVICES REPROCESSED | es_ES |
| dc.type | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| renati.advisor.dni | 10689893 | |
| renati.advisor.orcid | https://orcid.org/0000-0001-7403-6717 | |
| renati.author.dni | 43267493 | |
| renati.author.dni | 06251579 | |
| renati.discipline | 021209 | |
| renati.juror | Calsin Pacompia, Wilmer | |
| renati.juror | Arévalo Marcos, Rodolfo Amado | |
| renati.juror | Palomino Carrión, Ruby Cecilia | |
| renati.level | https://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad | |
| renati.type | https://purl.org/pe-repo/renati/type#trabajoAcademico | |
| thesis.degree.discipline | Segunda Especialidad de Gestión en Central de Esterilización | es_ES |
| thesis.degree.grantor | Universidad Privada Norbert Wiener. Facultad de Ciencias de la Salud | es_ES |
| thesis.degree.level | Título de Segunda Especialidad | es_ES |
| thesis.degree.name | Especialista de Gestión en Central de Esterilización | es_ES |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- TRABAJO ACADÉMICO Arrunátegui Marlene - Guzmán Henry.pdf
- Tamaño:
- 477.08 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Bloque de licencias
1 - 1 de 1
Cargando...

- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: