Comparative in vitro study of the resistance to fracture in two types of bis-acrylic resin, Lima – Peru 2021
| dc.contributor.advisor | Rojas Ortega, Raúl Antonio | |
| dc.contributor.author | Perez Acosta, Josefina | |
| dc.date.accessioned | 2022-02-21T15:07:26Z | |
| dc.date.available | 2022-02-21T15:07:26Z | |
| dc.date.issued | 2021-10-21 | |
| dc.description.abstract | The present study, titled "In vitro comparative study of fracture resistance in two types of bis-acrylic resins, Lima – Peru 2021," aimed to compare the fracture resistance of two types of bis-acrylic resins, Acrytemp® and Protemp 4™. A hypothetical-deductive method was used, with a quantitative, applied, cross-sectional, prospective, experimental approach, and a post-test experimental design. A sample of 36 bis-acrylic resin cylinders (Acrytemp® and Protemp 4™) was studied, divided into two groups of 18. These analysis units had dimensions of 4 mm in diameter by 8 mm in height and were subjected to compression using the CMT-5L LG universal testing machine. Results: The fracture resistance of Acrytemp® resin showed a mean of 150.9544 MPa, while Protemp 4™ resin showed a mean of 272.5817 MPa. Hypothesis testing using the Student's t-test yielded a p-value of 0.000, which is less than the significance level of p≤0.05, thus accepting the alternate hypothesis. Conclusion: There is a statistically significant difference in fracture resistance between the two types of bis-acrylic resins. | en_US |
| dc.description.abstract | El presente trabajo titulado “Estudio in vitro comparativo de la resistencia a la fractura en dos tipos de resina bis-acrílica, Lima – Perú 2021”, tuvo como objetivo comparar la resistencia a la fractura de dos tipos de resinas bis-acrílica Acrytem® y Protemp 4™. Se utilizó un método de investigación hipotético-deductivo, de enfoque cuantitativo, de tipo aplicada, transversal, prospectivo, experimental y de diseño experimental de posprueba. Se estudió una muestra de 36 cilindros de resinas bis-acrílicas Acrytemp® y Protemp 4TM, que se dividieron en dos grupos de 18, estas unidades de análisis tuvieron una dimensión de 4 mm de diámetro x 8 mm de altura y fueron sometidas a una compresión de la máquina de ensayo universal CMT-5L LG, obteniendo como resultados que la resistencia a la fractura de la resina bis-acrílica Acrytemp® presentó una media de 150.9544 Mpa, mientras que de la resina Protemp 4TM presentó una media de 272.5817, y la contrastación de hipótesis de la prueba T de Student obtuvo un p=0.000 por lo que al ser menor que el valor de significancia p≤0.05 se acepta la hipótesis alterna, concluyéndose que existe una diferencia estadísticamente significativa en la resistencia a la fractura de dos tipos de resinas bis-acrílicas. | es_ES |
| dc.description.researcharea | Salud, enfermedad y ambiente | |
| dc.format | application/pdf | |
| dc.identifier.uri | https://hdl.handle.net/20.500.13053/5580 | |
| dc.language.iso | spa | es_ES |
| dc.language.iso | spa | |
| dc.publisher | Universidad Privada Norbert Wiener | es_ES |
| dc.publisher.country | PE | es_ES |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.source | Repositorio Institucional de la Universidad Privada Norbert Wiener | es_ES |
| dc.subject | Resistencia a la fractura | es_ES |
| dc.subject | Resinas bis-acrílicas | es_ES |
| dc.subject | Estudio in vitro | es_ES |
| dc.subject | Fracture resistance | es_ES |
| dc.subject | Bis-acrylic resins | es_ES |
| dc.subject | In vitro study | es_ES |
| dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.14 | |
| dc.subject.ods | ODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades | |
| dc.title | Comparative in vitro study of the resistance to fracture in two types of bis-acrylic resin, Lima – Peru 2021 | en_US |
| dc.title | Estudio in vitro comparativo de la resistencia a la fractura en dos tipos de resina bis-acrílica, Lima – Perú 2021 | es_ES |
| dc.title.alternative | Comparative in vitro study of the resistance to fracture in two types of bis-acrylic resin, Lima – Peru 2021 | es_ES |
| dc.type | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| renati.advisor.dni | 07761772 | |
| renati.advisor.orcid | https://orcid.org/0000-0002-0165-7501 | |
| renati.author.dni | 43635576 | |
| renati.discipline | 911026 | |
| renati.juror | Menacho Angeles, Gregorio Lorenzo | |
| renati.juror | Robles Montesinos, Ada Olinda | |
| renati.juror | Puza Ramírez, Annyelo Fred | |
| renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | |
| renati.type | https://purl.org/pe-repo/renati/type#tesis | |
| thesis.degree.discipline | Odontología | es_ES |
| thesis.degree.grantor | Universidad Privada Norbert Wiener. Facultad de Ciencias de la Salud | es_ES |
| thesis.degree.level | Título Profesional | es_ES |
| thesis.degree.name | Cirujano Dentista | es_ES |

