Comparison of the roughness and compressive strength of type IV plasters subjected to manual and non-manual vibration according to time variation in vitro 2022
| dc.contributor.advisor | Morante Maturana, Sara Angelica | |
| dc.contributor.author | Sanchez Veramendi, Yoselina | |
| dc.date.accessioned | 2023-10-12T15:15:53Z | |
| dc.date.available | 2023-10-12T15:15:53Z | |
| dc.date.issued | 2023-07-07 | |
| dc.description.abstract | The purpose of this research was to compare the roughness and compression resistance of Type IV plasters subjected to manual and non-manual vibration, according to time variation. The study employed an applied methodology with an experimental, cross-sectional, prospective, and comparative design. The population consisted of two Type IV plasters subjected to manual and non-manual vibration, with a total of 120 plaster blocks from both brands. The sample consisted of 60 sample units for each commercial brand, subdivided into two groups of 30 units each, with 15 units measured at 30 minutes and 15 units at 60 minutes for compression and roughness measurements, respectively. A non-probabilistic convenience sampling was used according to the researcher's criteria. Two data collection forms were used: one for measuring compression resistance and another for measuring roughness, with the plasters used being Fujirock and Elite Rock. Results: Significant differences were observed when comparing the roughness between Elite Rock Type IV plaster and Fujirock, with a p-value of 0.001 (p < 0.05), and also in compression between Elite Rock Type IV plaster and Fujirock, with a p-value of 0.000 (p < 0.05). | en_US |
| dc.description.abstract | La presente investigación tuvo como propósito comparar la rugosidad y resistencia a la compresión de yesos tipo IV sometidos a vibrado manual y no manualsegún variación de tiempo. En el estudio se empleó una metodología de tipo aplicada y con un diseño experimental, transversal prospectivo y comparativo. La población estuvo conformada por dos yesos tipo IV sometidos a vibrado manual y no manual haciendo un total de 120 bloques de yeso de ambas marcas, la muestra correspondió a 60 unidades muestrales para cada marca comercial subdivididas en dos grupos de 30 unidades cada uno, con medición de 15 unidades a los 30 minutos y otras 15 unidades a los 60 minutos para compresión y para rugosidad respectivamente. Se realizó un muestreo no probabilístico elegidas por conveniencia de acuerdo a los criterios del investigador. Se hizo uso de dos fichas de recolección de datos, para la medición de resistencia a la compresión y otra para medición de la rugosidad, siendo los yesos empleados las marcas Fujirock y Elite rock. Como resultado se apreció que existen diferencias significativas al comparar la rugosidad entre el yeso tipo IV Elite rock y Fuji rock, el p-valor = 0.001 (p<0.05) y también en la compresión entre el yeso tipo IV Elite rock y Fujirock el p-valor = 0.000 (p<0.05) | es_ES |
| dc.description.researcharea | Salud y Bienestar | |
| dc.format | application/pdf | |
| dc.identifier.uri | https://hdl.handle.net/20.500.13053/9543 | |
| dc.language.iso | spa | es_ES |
| dc.language.iso | spa | |
| dc.publisher | Universidad Privada Norbert Wiener | es_ES |
| dc.publisher.country | PE | es_ES |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.source | Repositorio Institucional de la Universidad Privada Norbert Wiener | es_ES |
| dc.subject | Yeso tipo IV | es_ES |
| dc.subject | Rugosidad | es_ES |
| dc.subject | Resistencia a la compresión | es_ES |
| dc.subject | Type IV plaster | es_ES |
| dc.subject | Roughness | es_ES |
| dc.subject | Compression resistance | es_ES |
| dc.subject.ocde | https://purl.org/pe-repo/ocde/ford#3.02.14 | |
| dc.subject.ods | ODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades | |
| dc.title | Comparison of the roughness and compressive strength of type IV plasters subjected to manual and non-manual vibration according to time variation in vitro 2022 | en_US |
| dc.title | Comparación de la rugosidad y resistencia a la compresión de yesos tipo IV sometidos a vibrado manual y no manual según variación de tiempo in vitro, 2022 | es_ES |
| dc.title.alternative | Comparison of the roughness and compressive strength of type IV plasters subjected to manual and non-manual vibration according to time variation in vitro 2022 | es_ES |
| dc.type | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| renati.advisor.dni | 10138106 | |
| renati.advisor.orcid | https://orcid.org/0000-0001-9715-728X | |
| renati.author.dni | 42393390 | |
| renati.discipline | 911026 | |
| renati.juror | Luján Larreategui, Haydeé Giovanna | |
| renati.juror | Minaya Rondon, Omar | |
| renati.juror | Ocampo Guabloque, Helder Myriam | |
| renati.level | https://purl.org/pe-repo/renati/level#tituloProfesional | |
| renati.type | https://purl.org/pe-repo/renati/type#tesis | |
| thesis.degree.discipline | Odontología | es_ES |
| thesis.degree.grantor | Universidad Privada Norbert Wiener. Facultad de Ciencias de la Salud | es_ES |
| thesis.degree.level | Título Profesional | es_ES |
| thesis.degree.name | Cirujano Dentista | es_ES |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- T061_42393390_T.pdf
- Tamaño:
- 3.45 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
Cargando...

- Nombre:
- FORM_42393390_T.pdf
- Tamaño:
- 914.17 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Cargando...

- Nombre:
- TURNITIN_42393390_T.pdf
- Tamaño:
- 625.12 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Bloque de licencias
1 - 1 de 1
Cargando...

- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción:
