Adhesive strength of fiberglass bolts using two resinous cement systems. in vitro study. Lima Peru. 2021.

dc.contributor.advisorMenacho Angeles, Gregorio Lorenzo
dc.contributor.authorMuñoz Rodríguez, Senith Aide
dc.date.accessioned2023-02-01T01:45:42Z
dc.date.available2023-02-01T01:45:42Z
dc.date.issued2022-11-12
dc.description.abstractObjective: To compare the adhesive resistance of fiberglass posts using two resin cement systems. Methodology: 7 teeth were used for each cement type (Relyx U200 and RelyX Ultimate). A transverse cut was made at 2 mm from the cement-enamel junction on each tooth. The root canal treatment was then performed. For cementing with Relyx Ultimate, 37% phosphoric acid and Scotchbond universal adhesive were used beforehand, while for Relyx U200 cementing, the cement was applied directly. After cementing the fiberglass post, all teeth were cut into 1 mm thick discs, resulting in 6 discs. These root portion discs were taken to the DHL mechanical testing laboratory, where they underwent push-out testing to measure adhesive strength using a universal testing machine. Results: The adhesive strength of the fiberglass posts with Relyx Ultimate resin cement was 37 ± 14.59 Mpa in the cervical portion, 32.61 ± 8.44 Mpa in the middle portion, and 34.29 ± 9.13 Mpa in the apical portion. For Relyx U200 cement, the values were 34.05 ± 9.23 Mpa in the cervical portion, 38.43 ± 14.29 Mpa in the middle portion, and 30.15 ± 15.17 Mpa in the apical portion. Conclusion: No significant difference was found in the adhesive strength of fiberglass posts using the resin cement systems Relyx U200 and RelyX Ultimate in all three root thirds.en_US
dc.description.abstractObjetivo: Comparar la resistencia adhesiva de los pernos fibra de vidrio empleando dos sistemas de cementos resinosos. Metodología: Se emplearon 7 dientes para cada cemento (Relyx U200 y RelyX Ultimate) a estos dientes se les realizó un corte transversal a 2 mm de la unión cemento esmalte. Posteriormente se realizó el tratamiento de conductos. Para el cementado con cemento Relyx Ultimate se utilizó ácido fosfórico al 37% + adhesivo universal Scotchbond previamente, mientras que para el cementado con Relyx U200 el cementado fue directo. Todos los dientes después de cementar el perno fibra de vidrio, fueron cortados en discos de 1 mm de grosor, obteniéndose así 6 discos. Estos discos de las porciones radiculares fueron llevadas al laboratorio de ensayos mecánicos DHL, para por medio de una máquina de ensayos universales y la técnica de push-out generar la prueba de resistencia adhesiva. Resultados: La resistencia adhesiva de los pernos fibra de vidrio con el cemento resinoso Relyx Ultimate fue de 37 ± 14.59 Mpa en la porción cervical, 32.61 ± 8.44 Mpa en la porción media y 34.29 ± 9.13 Mpa en la porción apical, mientras que con el cemento Relyx U200 fue de 34.05 ± 9.23 Mpa en la porción cervical, 38.43 ± 14.29 Mpa en la porción media y 30.15 ± 15.17 Mpa en la porción apical. Conclusión: No existe diferencia significativa en la resistencia adhesiva de los pernos fibra de vidrio empleando los sistemas de cemento resinoso Relyx U200 y RelyX Ultimate en los tres tercios radiculares.es_ES
dc.description.researchareaSalud y Bienestar
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/7721
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectResistencia adhesivaes_ES
dc.subjectPernos fibra de vidrioes_ES
dc.subjectCementos resinososes_ES
dc.subjectAdhesive strengthes_ES
dc.subjectFiberglass postses_ES
dc.subjectResin cementses_ES
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.02.14
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleAdhesive strength of fiberglass bolts using two resinous cement systems. in vitro study. Lima Peru. 2021.en_US
dc.titleResistencia adhesiva de los pernos fibra de vidrio empleando dos sistemas de cementos resinosos. Estudio in vitro. Lima, Perú. 2021.es_ES
dc.title.alternativeAdhesive strength of fiberglass bolts using two resinous cement systems. in vitro study. Lima Peru. 2021.es_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni06039730
renati.advisor.orcidhttps://orcid.org/0000-0003-2283-0155
renati.author.dni76247048
renati.discipline911026
renati.jurorMorante Maturana, Sara Angélica
renati.jurorLujan Larreategui, Haydeé Giovanna
renati.jurorVilchez Bellido, Dina
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineOdontologíaes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo Profesionales_ES
thesis.degree.nameCirujano Dentistaes_ES

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
T061_76247048_T.pdf
Tamaño:
6.77 MB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
FORM_76247048_T.pdf
Tamaño:
147.71 KB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
TURNITIN_76247048_T.pdf
Tamaño:
4.46 MB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones