Análisis comparativo del método automatizado y lectura en lámina para el recuento plaquetario en pacientes del hospital San Bartolomé, 2024

dc.contributor.advisorHuamán Cárdenas, Víctor Raúl
dc.contributor.authorAtamari Lino, Katherine Elizabeth
dc.date.accessioned2025-04-16T21:14:12Z
dc.date.available2025-04-16T21:14:12Z
dc.date.issued2025-03-21
dc.description.abstractEl recuento plaquetario es una prueba fundamental en el diagnóstico y seguimiento de diversas condiciones médicas, ante una alarma de equipo automatizado se realiza una visualización en lámina periférica para realizar un conteo manual confirmatorio. En distinta lugares como centros de salud o postas, especialmente en áreas rurales o con recursos limitados, los métodos manuales siguen siendo la principal opción debido a la falta de equipos automatizados. Objetivo: Este estudio busca comparar la concordancia analítica entre el método automatizado y las diferentes metodologías de lectura en lámina para el recuento estimado de plaquetas en pacientes del Hospital san Bartolomé, 2024. Materiales y métodos: Se utilizó un diseño de investigación no experimental, transversal y de enfoque cuantitativo. Los datos fueron analizados mediante el coeficiente de correlación de concordancia (CCC) y se aplicaron pruebas estadísticas para determinar la concordancia entre los métodos. El estudio se realizó en el Hospital San Bartolomé, utilizando 131 muestras sanguíneas de pacientes adultos. Se compararon tres métodos de recuento plaquetario: el método automatizado, el método de Fonio y el método del Factor 20 000. Las muestras fueron procesadas en el equipo automatizado de hematología y, posteriormente, se realizaron frotis sanguíneos para los métodos manuales. Los frotis fueron teñidos con Wright Giemsa y evaluados por el encargado del área de hematología. Resultados: Los resultados mostraron una alta concordancia analítica entre el método automatizado y el método de Fonio, con un coeficiente de correlación de concordancia (CCC) de 0.964. En cambio, la concordancia entre el método automatizado y el Factor 20,000 fue de 0.926, indicando una concordancia media. La comparación entre los métodos manuales (Fonio y Factor 20,000) arrojó un CCC de 0.905. Conclusión: El estudio concluye que el método automatizado es el más preciso y confiable para el recuento plaquetario, pero el método de Fonio puede ser una herramienta complementaria, efectiva y también confiable en situaciones donde no se dispone de tecnología avanzada como centros de salud o postas medicas donde la accesibilidad económica y tecnológica es desprotegida.es_ES
dc.description.abstractThe platelet count is a fundamental test in the diagnosis and monitoring of various medical conditions. When an automated equipment alarm is triggered, a peripheral blood smear is examined to perform a confirmatory manual count. In various settings, such as health centers or clinics, especially in rural or resource-limited areas, manual methods remain the primary option due to the lack of automated equipment. Objective: This study aims to compare the analytical agreement between the automated method and different manual slide-reading methodologies for estimating platelet counts in patients at the Hospital San Bartolomé, 2024. Materials and methods: A non-experimental, cross-sectional, and quantitative research design was used. Data were analyzed using the concordance correlation coefficient (CCC), and statistical tests were applied to determine agreement between the methods. The study was conducted at the Hospital San Bartolomé, using 131 blood samples from adult patients. Three platelet count methods were compared: the automated method, the Fonio method, and the 20,000 Factor method. Samples were processed using an automated hematology analyzer, and subsequently, blood smears were prepared for manual methods. The smears were stained with Wright-Giemsa and evaluated by the hematology department staff. Results: The results showed a high analytical agreement between the automated method and the Fonio method, with a concordance correlation coefficient (CCC) of 0.964. In contrast, the agreement between the automated method and the 20,000 Factor method was 0.926, indicating moderate agreement. The comparison between the manual methods (Fonio and 20,000 Factor) yielded a CCC of 0.905. Conclusion: The study concludes that the automated method is the most accurate and reliable for platelet counting. However, the Fonio method can serve as a complementary and effective tool in situations where advanced technology is unavailable, such as in health centers or medical posts where economic and technological accessibility is limited.en_US
dc.description.researchareaTecnologías emergentes y experimentación en salud.
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/13133
dc.language.isospaes_ES
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.subjectPlaquetases_ES
dc.subjectBlood Plateletsen_US
dc.subjectMedidas de Correlaciónes_ES
dc.subjectCorrelation Measuresen_US
dc.subjectRecuento de Plaquetases_ES
dc.subjectPlatelet Counten_US
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#2.06.02
dc.subject.ocdehttps://purl.org/pe-repo/ocde/ford#3.01.09
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleAnálisis comparativo del método automatizado y lectura en lámina para el recuento plaquetario en pacientes del hospital San Bartolomé, 2024es_ES
dc.title.alternativeComparative analysis of the automated method and sheet reading for platelet count in patients of the San Bartolomé Hospital, 2024en_US
dc.typeinfo:eu-repo/semantics/bachelorThesis
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublication
renati.advisor.dni70092305
renati.advisor.orcidhttps://orcid.org/0000-0002-6371-4559
renati.author.dni75110164
renati.discipline915126
renati.jurorCossio Villar, Mery Ann
renati.jurorValenzuela Martinez, Stefany Saragoza
renati.jurorLaynes Hernandez, Diana Elizabeth
renati.levelhttps://purl.org/pe-repo/renati/level#tituloProfesional
renati.typehttps://purl.org/pe-repo/renati/type#tesis
thesis.degree.disciplineTecnología Médica en Laboratorio Clínico y Anatomía Patológicaes_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo profesionales_ES
thesis.degree.nameLicenciada en Tecnología Médica en Laboratorio Clínico y Anatomía Patológicaes_ES

Archivos

Bloque original

Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
T061_75110164_T.pdf
Tamaño:
1.31 MB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
FORM_75110164_T.pdf
Tamaño:
209.05 KB
Formato:
Adobe Portable Document Format
Cargando...
Miniatura
Nombre:
TURNITIN_75110164_T.pdf
Tamaño:
1.28 MB
Formato:
Adobe Portable Document Format

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
15.18 KB
Formato:
Item-specific license agreed upon to submission
Descripción: