dc.description.abstractObjective: Systematize evidence of closed-circuit endotracheal aspiration compared to open-circuit to reduce complications in patients with mechanical ventilation in trauma shock. Material and Method: Systematic observational and retrospective quantitative review, subjected to critical selection, using the Grade evaluation system found in the following database: PubMed, Redalyc, Cochrane, Lylacs, Scielo. Of the 10 articles systematically reviewed with the period 2008 – 2018, 60% (n=6/10) are a systematic review, 10% (n=1/10) are a prospective randomized study, 10% (n=1/10 ) experimental study, 10% (n=1/10) randomized crossover study and 10% (n=1/10) clinical trial, of which had different origins such as: Brazil (30%), China (10%), Japan (10%), Iran (10%), USA (10%), Colombia (10%), Sweden (10%) and Australia (10% ). Results: the evidence found at 100% (n=10/10) indicates that the use of a closed endotracheal suction system has fewer complications than the open system in patients with mechanical ventilation. Conclusion: according to the evidence analyzed from 10 100% scientific articles, 70% conclude that there are greater complications in the open endotracheal aspiration system than the closed endotracheal aspiration system in patients with mechanical ventilation and 30% do not compare their effectiveness in the use of both endotracheal suction circuits.en_US
dc.description.abstractObjetivo: Sistematizar evidencias de la aspiración endotraqueal circuito cerrado comparado con circuito abierto para disminuir complicaciones en pacientes con ventilación mecánica en shock trauma. Material y Método: Revisión sistemática observacional y retrospectiva de tipo cuantitativa, sometidos a selección critica, utilizando el sistema de evaluación Grade hallados en la siguiente base de datos: PubMed, Redalyc, Cochrane, Lylacs, Scielo. De los 10 artículos revisados sistemáticamente con periodo 2008 – 2018, un 60% (n=6/10) son de revisión sistemática, un 10% (n=1/10) estudio prospectivo aleatorizado , un 10% (n=1/10) estudio experimental, un 10% (n=1/10) estudio aleatorio cruzado y un 10% (n=1/10) ensayo clínico, de los cuales tuvieron distintas procedencias como: Brasil (30%), China (10%), Japón (10%), Irán (10%), USA (10%), Colombia (10%), Suecia (10%) y Australia (10%). Resultados: las evidencias encontradas al 100% (n=10/10) señalan que el uso de sistema de aspiración endotraqueal cerrado tiene menores complicaciones que el sistema abierto en pacientes con ventilación mecánica. Conclusión: según las evidencias analizadas de 10 artículos científicos 100%, el 70% concluye que existe mayores complicaciones en el sistema de aspiración endotraqueal abierto que el sistema de aspiración endotraqueal cerrado en pacientes con ventilación mecánica y el 30% no compara su eficacia en el uso de ambos circuitos de aspiración endotraqueal.es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/3670
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectInfeccioneses_ES
dc.subjectUnidades de Cuidados Intensivoses_ES
dc.subjectVentilación Mecánicaes_ES
dc.subjectChoque Traumáticoes_ES
dc.subjectInfectionses_ES
dc.subjectIntensive Care Unitses_ES
dc.subjectMechanical Ventilationes_ES
dc.subjectShock, Traumatices_ES
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#3.03.03
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleEffectiveness of endotracheal suction in a closed circuit compared to an open circuit to reduce complications in mechanically ventilated trauma patients in shocken_US
dc.titleEfectividad de la aspiración endotraqueal en circuito cerrado comparado con circuito abierto para la disminución de complicaciones en pacientes con ventilación mecánica en shock traumaes_ES
dc.title.alternativeEFFECTIVENESS OF ENDOTRACHEAL ASPIRATION IN CLOSED CIRCUIT COMPARED TO OPEN CIRCUIT FOR THE REDUCTION OF COMPLICATIONS IN PATIENTS WITH MECHANICAL VENTILATION IN SHOCK TRAUMA.es_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni46370194
renati.advisor.orcidhttps://orcid.org/0000-0002-4633-2997
renati.author.dni71653863
renati.discipline021069
renati.jurorMori Castro, Jaime Alberto
renati.jurorUturunco Vera, Milagros Lizbeth
renati.jurorFernández Rengifo, Werther Fernando
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#trabajoAcademico
thesis.degree.disciplineSegunda Especialidad en Cuidado Enfermero en Emergencias y Desastreses_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista en Cuidado Enfermero en Emergencias y Desastreses_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
T061_71653863_S.pdf
Tamaño:
918.86 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones