Effectiveness of secretions aspiration in a closed circuit versus open circuit in preventing ventilator-associated pneumonia in ICU patients

dc.contributor.advisorUturunco Vera, Milagros Lizbeth
dc.contributor.authorQuispe Inga, Dennys
dc.contributor.authorNajarro Nuñez, Alex Nelson
dc.date.accessioned2019-07-03T16:05:00Z
dc.date.available2019-07-03T16:05:00Z
dc.date.issued2019-05-19
dc.description.abstractObjective: Systematize the evidence on the effectiveness of closed versus open circuit aspiration of secretions in the prevention of pneumonia associated with mechanical ventilators in patients treated in the ICU. Material and Methods: International articles are systematically reviewed by searching the Pubmed, Elsevier and Science Direct databases, which are analyzed through the grade system, using DECS and MESH descriptors. When evaluating the articles, the result was that 100% (10/10) of the articles correspond to Brazil, England, Japan, the United States, China, India, Egypt, Korea, Switzerland and Iran respectively. Results: 90% (09/10) of the evidence indicates that the effectiveness is similar between open and closed endotracheal suction systems in the prevention of ventilator-associated pneumonia in patients hospitalized in the ICU, and 10% (01/ 10) indicate that the closed circuit is more effective than the open one. Conclusions: It is found that 09 of the 10 evidence conclude that the effectiveness is similar between open and closed endotracheal suction systems in the prevention of ventilator-associated pneumonia in patients hospitalized in the ICU, and 01 of 10 indicate that the closed circuit is more effective than open. Furthermore, both treated systems did not show desaturation.en_US
dc.description.abstractObjetivo: Sistematizar la evidencia sobre la efectividad en la aspiración de secreciones del circuito cerrado versus el abierto en la prevención de la neumonía asociada al ventilador mecánico en pacientes atendidos en UCI. Material y Métodos: Se revisa sistemáticamente artículos internacionales, mediante búsqueda en las bases de datos Pubmed, Elsevier y Science Direct, las que se analizan mediante el sistema grade, utilizando descriptores DECS y MESH. Al efectuar la evaluación de los artículos se obtuvo como resultado que el 100% (10/10) de los artículos corresponden a Brasil, Inglaterra, Japón, Estados Unidos, China, India, Egipto, Korea, Suiza e Iran respectivamente. Resultados: el 90% (09/10) de las evidencias indican que la efectividad es similar entre los sistemas de succión endotraqueal abierto y cerrado en la prevención de la neumonía asociada al ventilador en pacientes hospitalizados en UCI, y el 10% (01/10) indican que es más efectivo el circuito cerrado que el abierto. Conclusiones: Se encuentra que 09 de las 10 evidencias concluyen que la efectividad es similar entre los sistemas de succión endotraqueal abierto y cerrado en la prevención de la neumonía asociada al ventilador en pacientes hospitalizados en UCI, y 01 de 10 indican que el circuito cerrado es más efectivo que el abierto. Además, ambos sistemas tratados no mostraron desaturación .es_ES
dc.description.researchareaSalud, enfermedad y ambiente
dc.formatapplication/pdf
dc.identifier.urihttps://hdl.handle.net/20.500.13053/2984
dc.language.isospaes_ES
dc.language.isospa
dc.publisherUniversidad Privada Norbert Wieneres_ES
dc.publisher.countryPEes_ES
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/
dc.sourceRepositorio Institucional de la Universidad Privada Norbert Wieneres_ES
dc.subjectSucciónes_ES
dc.subjectEnfermeríaes_ES
dc.subjectNeumonía Asociada al Ventiladores_ES
dc.subjectUnidad de Cuidados Intensivoses_ES
dc.subjectSuctiones_ES
dc.subjectNursinges_ES
dc.subjectPneumonia, Ventilator-Associatedes_ES
dc.subjectIntensive Care Unitses_ES
dc.subject.ocdehttp://purl.org/pe-repo/ocde/ford#3.03.03
dc.subject.odsODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades
dc.titleEffectiveness of secretions aspiration in a closed circuit versus open circuit in preventing ventilator-associated pneumonia in ICU patientsen_US
dc.titleEfectividad en la aspiración de secreciones del circuito cerrado versus circuito abierto en la prevención de la neumonía asociada al ventilador mecánico en pacientes atendidos en la unidad de cuidados intensivoses_ES
dc.title.alternativeEffecti veness in the aspiration of secretions of the closed circuit versus open circuit in the prevention of pneumonia associated to the mechanical ventilator in patients attended in the intensive care unites_ES
dc.typehttp://purl.org/coar/resource_type/c_7a1f
dc.type.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
renati.advisor.dni44551282
renati.advisor.orcidhttps://orcid.org/0000-0002-8482-1281
renati.author.dni42915109
renati.author.dni40485040
renati.discipline913479
renati.jurorBonilla Asalde, Cesar Antonio
renati.jurorCalsin Pacompia, Wilmer
renati.jurorZavaletaGutierrez, Violeta Aiide
renati.levelhttps://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad
renati.typehttps://purl.org/pe-repo/renati/type#trabajoAcademico
thesis.degree.disciplineSegunda Especialidad en Enfermería en Cuidados Intensivoses_ES
thesis.degree.grantorUniversidad Privada Norbert Wiener. Facultad de Ciencias de la Saludes_ES
thesis.degree.levelTítulo de Segunda Especialidades_ES
thesis.degree.nameEspecialista en Enfermería en Cuidados Intensivoses_ES

Archivos

Bloque original

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
TRABAJO ACADÉMICO Najarro Alex - Quispe Dennys.pdf
Tamaño:
935.82 KB
Formato:
Adobe Portable Document Format
Descripción:

Bloque de licencias

Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones