Effectiveness of secretions aspiration in a closed circuit versus open circuit in preventing ventilator-associated pneumonia in ICU patients
| dc.contributor.advisor | Uturunco Vera, Milagros Lizbeth | |
| dc.contributor.author | Quispe Inga, Dennys | |
| dc.contributor.author | Najarro Nuñez, Alex Nelson | |
| dc.date.accessioned | 2019-07-03T16:05:00Z | |
| dc.date.available | 2019-07-03T16:05:00Z | |
| dc.date.issued | 2019-05-19 | |
| dc.description.abstract | Objective: Systematize the evidence on the effectiveness of closed versus open circuit aspiration of secretions in the prevention of pneumonia associated with mechanical ventilators in patients treated in the ICU. Material and Methods: International articles are systematically reviewed by searching the Pubmed, Elsevier and Science Direct databases, which are analyzed through the grade system, using DECS and MESH descriptors. When evaluating the articles, the result was that 100% (10/10) of the articles correspond to Brazil, England, Japan, the United States, China, India, Egypt, Korea, Switzerland and Iran respectively. Results: 90% (09/10) of the evidence indicates that the effectiveness is similar between open and closed endotracheal suction systems in the prevention of ventilator-associated pneumonia in patients hospitalized in the ICU, and 10% (01/ 10) indicate that the closed circuit is more effective than the open one. Conclusions: It is found that 09 of the 10 evidence conclude that the effectiveness is similar between open and closed endotracheal suction systems in the prevention of ventilator-associated pneumonia in patients hospitalized in the ICU, and 01 of 10 indicate that the closed circuit is more effective than open. Furthermore, both treated systems did not show desaturation. | en_US |
| dc.description.abstract | Objetivo: Sistematizar la evidencia sobre la efectividad en la aspiración de secreciones del circuito cerrado versus el abierto en la prevención de la neumonía asociada al ventilador mecánico en pacientes atendidos en UCI. Material y Métodos: Se revisa sistemáticamente artículos internacionales, mediante búsqueda en las bases de datos Pubmed, Elsevier y Science Direct, las que se analizan mediante el sistema grade, utilizando descriptores DECS y MESH. Al efectuar la evaluación de los artículos se obtuvo como resultado que el 100% (10/10) de los artículos corresponden a Brasil, Inglaterra, Japón, Estados Unidos, China, India, Egipto, Korea, Suiza e Iran respectivamente. Resultados: el 90% (09/10) de las evidencias indican que la efectividad es similar entre los sistemas de succión endotraqueal abierto y cerrado en la prevención de la neumonía asociada al ventilador en pacientes hospitalizados en UCI, y el 10% (01/10) indican que es más efectivo el circuito cerrado que el abierto. Conclusiones: Se encuentra que 09 de las 10 evidencias concluyen que la efectividad es similar entre los sistemas de succión endotraqueal abierto y cerrado en la prevención de la neumonía asociada al ventilador en pacientes hospitalizados en UCI, y 01 de 10 indican que el circuito cerrado es más efectivo que el abierto. Además, ambos sistemas tratados no mostraron desaturación . | es_ES |
| dc.description.researcharea | Salud, enfermedad y ambiente | |
| dc.format | application/pdf | |
| dc.identifier.uri | https://hdl.handle.net/20.500.13053/2984 | |
| dc.language.iso | spa | es_ES |
| dc.language.iso | spa | |
| dc.publisher | Universidad Privada Norbert Wiener | es_ES |
| dc.publisher.country | PE | es_ES |
| dc.rights | http://purl.org/coar/access_right/c_abf2 | |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.source | Repositorio Institucional de la Universidad Privada Norbert Wiener | es_ES |
| dc.subject | Succión | es_ES |
| dc.subject | Enfermería | es_ES |
| dc.subject | Neumonía Asociada al Ventilador | es_ES |
| dc.subject | Unidad de Cuidados Intensivos | es_ES |
| dc.subject | Suction | es_ES |
| dc.subject | Nursing | es_ES |
| dc.subject | Pneumonia, Ventilator-Associated | es_ES |
| dc.subject | Intensive Care Units | es_ES |
| dc.subject.ocde | http://purl.org/pe-repo/ocde/ford#3.03.03 | |
| dc.subject.ods | ODS 3: Salud y bienestar. Garantizar una vida sana y promover el bienestar de todos a todas las edades | |
| dc.title | Effectiveness of secretions aspiration in a closed circuit versus open circuit in preventing ventilator-associated pneumonia in ICU patients | en_US |
| dc.title | Efectividad en la aspiración de secreciones del circuito cerrado versus circuito abierto en la prevención de la neumonía asociada al ventilador mecánico en pacientes atendidos en la unidad de cuidados intensivos | es_ES |
| dc.title.alternative | Effecti veness in the aspiration of secretions of the closed circuit versus open circuit in the prevention of pneumonia associated to the mechanical ventilator in patients attended in the intensive care unit | es_ES |
| dc.type | http://purl.org/coar/resource_type/c_7a1f | |
| dc.type.version | http://purl.org/coar/version/c_970fb48d4fbd8a85 | |
| renati.advisor.dni | 44551282 | |
| renati.advisor.orcid | https://orcid.org/0000-0002-8482-1281 | |
| renati.author.dni | 42915109 | |
| renati.author.dni | 40485040 | |
| renati.discipline | 913479 | |
| renati.juror | Bonilla Asalde, Cesar Antonio | |
| renati.juror | Calsin Pacompia, Wilmer | |
| renati.juror | ZavaletaGutierrez, Violeta Aiide | |
| renati.level | https://purl.org/pe-repo/renati/level#tituloSegundaEspecialidad | |
| renati.type | https://purl.org/pe-repo/renati/type#trabajoAcademico | |
| thesis.degree.discipline | Segunda Especialidad en Enfermería en Cuidados Intensivos | es_ES |
| thesis.degree.grantor | Universidad Privada Norbert Wiener. Facultad de Ciencias de la Salud | es_ES |
| thesis.degree.level | Título de Segunda Especialidad | es_ES |
| thesis.degree.name | Especialista en Enfermería en Cuidados Intensivos | es_ES |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- TRABAJO ACADÉMICO Najarro Alex - Quispe Dennys.pdf
- Tamaño:
- 935.82 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Bloque de licencias
1 - 1 de 1
Cargando...

- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: